Trials / Unknown
UnknownNCT04977115
Clinical Evaluation of Intraocular Caliper-assisted Capsulotomy for Age-related Cataract
Comparison of Intraocular Caliper-assisted and Verion Navigation System-assisted Capsulotomy in Phacoemulsification Surgery: A Randomized Non-inferiority Trial
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 156 (estimated)
- Sponsor
- Zhongshan Ophthalmic Center, Sun Yat-sen University · Academic / Other
- Sex
- All
- Age
- 55 Years – 80 Years
- Healthy volunteers
- Not accepted
Summary
The purpose of this study is to compare the accuracy of capsulotomy assisted by intraocular caliper and Verion navigation system in phacoemulsification surgery and postoperative visual quality of patients.
Detailed description
Continuous curvilinear capsulorhexis (CCC) is an important and technically challenging procedure in cataract surgery. However, most surgeons perform CCC by experience or referring to the pupil size, which is highly subjective and the accuracy of capsulorhexis is unsatisfactory. The investigators developed a new modified intraocular caliper with standard calibration on the rinse needle, which can measure and locate the position of capsulorhexis. The surgeon can gently use the blunt needle in the front of the intraocular caliper to further make corresponding markers on the lens anterior capsule, and then carry out capsulotomy according to the marks. We found intraocular caliper-assisted capsulotomy can obviously improve the accuracy of capsulorhexis. The purpose of this study is to compare the accuracy and postoperative visual quality of intraocular caliper-assisted capsulotomy with those of digital image projection device VERION navigation system.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Intraocular caliper-assisted capsulotomy | Intraocular caliper is a modified intraocular caliper with standard calibration on the rinse needle. |
| PROCEDURE | Verion navigation system-assisted capsulotomy | Verion Image Guided System (Alcon Laboratories, Inc.) is a digital image guidance system consisting of a diagnostic reference unit and a surgery pilot for intraoperative surgical assistance. The device can be used to align toric intraocular lens during surgery as well as support manual creation of a capsulorhexis with a predefined target diameter. |
Timeline
- Start date
- 2021-07-26
- Primary completion
- 2022-02-28
- Completion
- 2022-04-30
- First posted
- 2021-07-26
- Last updated
- 2021-07-26
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT04977115. Inclusion in this directory is not an endorsement.