Clinical Trials Directory

Trials / Unknown

UnknownNCT04857229

Histolog Comparison to Standard Histology

Do the Results of Intra-operative Margin Assessment Correlate With the Output of Conventional Histology for Patient Undergoing Breast Conservation Surgery?

Status
Unknown
Phase
Study type
Observational
Enrollment
101 (actual)
Sponsor
Imperial College London · Academic / Other
Sex
Female
Age
18 Years
Healthy volunteers
Not accepted

Summary

This is a clinical device trial to assess the accuracy of margin assessment for a confocal scanning device (Histolog Scanner) at assessing the margins of breast tissue following wide local excision surgery.

Detailed description

Currently a 15-20% of breast cancer patients have cancer cells seen at the edge of the tissue removed following. These patient will need to undergo a second operation to ensure all the cancer cells are removed, which has psychological, cosmetic and cost implications. Several technologies have been designed to allow the edges of tissue to be tested during surgery, with the most accurate being those that involve assessing the tissue edge at a cellular level. However, these techniques are time consuming which makes their use in routine work impractical. The Histolog system uses pinhole (confocal) microscopy to capture cellular level images of the edge of tissue intra-operatively. The first generation of the device has been shown to be accurate for assessing breast tissue biopsies and skin cancer. The second generation of the device has an 8cm plate for scanning tissue and is CE marked for the assessment of tissue margins. This project is to show that the device is accurate for the assessment of margins, with further assessment in relation to the time for images to be captured and ease of interpretation to assess overall feasibility. The study would recruit at a single high volume breast cancer centre. The study will recruit patients with a diagnosis of breast cancer who are due to undergo breast conservation surgery (lumpectomy) with inclusion criteria of female patients over the age of 18 who are able to give informed consent. The study would involve the edges of removed tissue being imaged following surgery. These images would be reported by a consultant histopathologist and compared to the routine gold standard histology. There is no change to patient care and the device will not be used to change the surgery performed. There are no questionnaires or additional demands placed on the participants.

Conditions

Interventions

TypeNameDescription
DEVICEHistolog ScannerConfocal Microscope

Timeline

Start date
2021-06-04
Primary completion
2023-12-01
Completion
2023-12-01
First posted
2021-04-23
Last updated
2023-02-14

Locations

1 site across 1 country: United Kingdom