The Use of the Tip Stim Glove Device to Achieve Coordinated Movement of the Human Hand

Influence of the Tested Position and the Use of the TipStim Glove Device on the Improvement of the Hand Motor Coordination After Stroke

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
29 (actual)
Sponsor
Anna Olczak · Academic / Other
Sex
All
Age
42 Years – 89 Years
Healthy volunteers
Not accepted

Summary

The study was to evaluate the use of the Tip Stim device to achieve coordinated movement and grip force in stroke patients under conditions of active and passive stabilization of the trunk.

Detailed description

To test the effectiveness of the Tip Stim device, each patient received (alternating) both the experimental and control treatments in a specific sequence to assess the coordination of human hand movement and the grip strength. The first therapy with the use of Tip Stim parameters (Ratio current time to pause time: 2 sec :5 sec; Ramp (rise time impulse): 0,3 sec; Frequency: 20 Hz; Pulse width: 300 µs). Another session (putting on the glove without setting any parameters) took place after a week (time to mute the effects of the intervention). The duration of each therapy session is 60 minutes. After the first therapeutic session and after a week, the parameters of movement coordination and hand grip were examined. The study of motor coordination and grip strength was performed in two different starting positions: sitting (no stabilization) (fig. 1) and lying (with stabilization) (fig. 2), and with a different position of the examined upper limb. During the first examination, the subject sat on a treatment table, feet resting on the floor. Upper limb examined in adduction, with bent elbow joint in the intermediate position between pronation and supination of the forearm. In the supine examination, the upper limb was stabilized against the subject's body (adduction in the shoulder joint, flexion in the elbow joint in an intermediate position). In each of the starting positions, first after putting on the glove, the range of passive motion in the radial-wrist joint (flexion and extension) and fingers (global flexion and extension) was measured, then the active movement was measured, in the sequence as above. Eventually, they were asked to make movements as quickly and as fully as possible. Measurement of the grip force with a dynamometer was performed in both analyzed starting positions after testing the ranges of motion and speed/frequency. The Hand Tutor device and the EH 101 electronic hand dynamometer measuring the strength of the handgrip (measurement error 0.5 kg / 1 lb) were used to test the parameters of motor coordination and grip strength. The Hand Tutor is a device with a rehabilitation program and the ability to measure the range of passive and active movement, deficits of movement (error of measurement, 5 - 10 mm) as well as the speed/frequency of movement (error of measurement, 0,5 cycle/sec.).

Conditions

Interventions

TypeNameDescription
PROCEDUREhand motor coordination in a sitting position after use TipStim GloveThe next therapy with the use of Tip Stim took place after a week. The duration of each therapy session was 60 minutes. After the first therapy session and after a week, the parameters of movement coordination and handgrip were examined. The study of motor coordination and grip strength was performed in two different starting positions: sitting (no stabilization) and lying (with stabilization), and with a different position of the examined upper limb. The upper limb was examined in adduction, with the bent elbow joint in the intermediate position of the forearm. In each of the starting positions, first, the range of passive motion in the wrist joint (flexion and extension) and fingers (global flexion and extension) was measured, then the active movement was measured, in the sequence as above. Patients were asked to make movements as quickly and as fully as possible. Measurement of the grip force was performed after testing the ranges of motion and speed/frequency.

Timeline

Start date
2019-07-10
Primary completion
2020-02-14
Completion
2020-02-14
First posted
2021-04-01
Last updated
2021-04-01

Locations

1 site across 1 country: Poland

Source: ClinicalTrials.gov record NCT04825405. Inclusion in this directory is not an endorsement.