Clinical Trials Directory

Trials / Completed

CompletedNCT04817059

Reducing Head Motion With Customized Head Mold in Young Children

The Impact of Customized Head Molds on Motion and Motion-related Artifacts From Structural and Functional MRI Scans in Children

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
21 (actual)
Sponsor
University of Texas at Austin · Academic / Other
Sex
All
Age
5 Years – 10 Years
Healthy volunteers
Accepted

Summary

The purpose of this study is to assess the safety and efficacy of a customized head mold for reducing head motion during MRI scanning in young children.

Detailed description

Each participant completed a dedicated session for mock scanning before we acquired two sets of sMRI and fMRI scans. One scan set was collected using the head mold and the other without, and the scans were counterbalanced in order across participants. Using a specialized sMRI sequence embedded with vNAVs, we directly measured head motion during sMRI in order to more accurately evaluate the head mold's impact on structural metrics. To evaluate the feasibility and tolerability of the head mold, we concluded the scanning sessions with a brief interview that gauged participants' scanning experience and tolerance of the head mold. We investigated whether head molds would reduce head motion compared to standard scanning procedures and whether those reductions would result in improved data quality. We also tested the extent to which reductions in head motion impacted estimations of cortical volume and functional connectivity. Prior to data collection, we evaluated the noise dosage levels of the head mold condition, given the limited space available for additional hearing protection devices in the head coil while the head mold is on. We also assessed whether the head molds could balance head motion between typical and ADHD populations, and whether clinical variables such as ADHD diagnosis and trait anxiety, as determined by parent-reported dimensional measures, can predict head mold efficacy.

Conditions

Interventions

TypeNameDescription
DEVICECaseforge headcaseWe used a custom-fitted styrofoam head mold designed to reduce head motion during MRI scanning.

Timeline

Start date
2018-06-19
Primary completion
2019-08-08
Completion
2019-08-08
First posted
2021-03-25
Last updated
2021-03-25

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT04817059. Inclusion in this directory is not an endorsement.