Clinical Trials Directory

Trials / Unknown

UnknownNCT04795401

The Effectiveness of FRAME FR for AVF Repair in High-Flow Reduction & Stabilization, A Prospective Trial

The Effectiveness of FRAME FR for ArterioVenous Fistula Repair in High-Flow Reduction, A Prospective, Monocenter Controlled Trial

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
21 (actual)
Sponsor
Fondation Hôpital Saint-Joseph · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Patients with end-stage renal disease require permanent vascular access to enable safe and effective hemodialysis. An arteriovenous fistula (AVF), where a vein is mobilized and connected to an artery in the arm, is considered the gold standard and first choice for vascular access. After fistula creation, the vein is subjected to high pressure and flow, and undergoes remodeling. This includes the possibility of significant dilatation and intimal hyperplasia. Normal AVF flow required for effective dialysis is around 0.6 liters/min or 0.4-0.8 liters/min. However, in at least 20% of patients, excessive remodeling and dilatation of the fistula result in a high flow AVF with \>2 liters/min. High flow fistulas significantly increase the risk for the development of high output cardiac failure, skin breakdown, bleeding, hand ischemia, and other systemic complications. In cases of high flow AVF, venous reconstruction procedures, banding and/or plication, are often required to limit venous diameter and flow. The longevity of this procedure is limited as the reconstructed segment remodels and re-dilates due to ongoing arterial pressure. Banding and plication are both procedures that are designed to increase resistance to flow. Banding is performed by wrapping a segment of polytetrafluoroethylene (PTFE) around the outflow tract of the fistula, or by placing a suture around the fistula near the arterial anastomotic area to create a narrowing. Fistula plication involves narrowing of a short segment of the proximal venous outflow tract, usually accomplished by suturing or stapling the fistula for 2-6 cm. One of the notable systemic effects of a hemodialysis AVF is an acute decrease in systemic vascular resistance with a simultaneous increase in venous return to the heart, and thus an increase of the cardiac output. Cardiac failure occurs more frequently in patients with an access flow QA\>2 l/min and CPR≥20%. Another adverse systemic effect of AV fistulas is pulmonary hypertension. The increased flow volume to the heart from an AV fistula yields an increase in pulmonary pressures. This can limit pulmonary vasodilation and result in pulmonary hypertension.

Conditions

Interventions

TypeNameDescription
DEVICEFRAME FR IFUThe surgeon will use the medical device FRAME to perform the plication procedure. The device will be selected and implanted according to the product IFU.

Timeline

Start date
2021-04-06
Primary completion
2023-04-05
Completion
2024-04-05
First posted
2021-03-12
Last updated
2023-09-13

Locations

1 site across 1 country: France

Source: ClinicalTrials.gov record NCT04795401. Inclusion in this directory is not an endorsement.