Trials / Completed
CompletedNCT04794725
MOVIDA 1 Ter - Evaluation of the Cobas® Plasma Separation Card in the Field in Vietnam
Monitoring Of Viral Load In Decentralised Area 1 Ter - Evaluation of the Cobas® Plasma Separation Card in the Field in Vietnam
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 250 (actual)
- Sponsor
- Institut Pasteur · Industry
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
In low- and middle-income countries, viral load (VL) monitoring of patients living with HIV and followed on antiretroviral therapy (ART) in remote settings is still scarce. Barriers to VL monitoring are essentially the limited access to a laboratory able to perform this measurement, its cost, as well as the lack of human and material resources. Blood sampling using dried blood spots (DBS), which has been validated and is immediately available, could overcome these barriers. With DBS, transfer and conservation of samples are simplified enabling access to VL monitoring to patients seeking care in sites far from laboratory facilities. Use of DBS also offers the advantage not to require extensive investments. To guide decision makers in the implementation of strategies to scale-up HIV VL monitoring in remote settings, field evaluations of DBS in routine conditions are needed. It is in this context that we propose this field evaluation of the Cobas® plasma separation card in Vietnam
Detailed description
In Vietnam, in 2018, HIV prevalence was estimated at 0.3% among adults and the estimated proportion of PLHIV on ART was 65%, however the HIV epidemic is essentially concentrated in people who inject drugs, men who have sex with men and sex workers. As of today, routine HIV VL monitoring is not yet available in remote settings in Vietnam. Despite an initiative we conducted and that documented the feasibility of DBS use in remote settings, and although no genuine roll-out of POC machines is yet observed in the field, the Ministry of Health of Vietnam has not yet decided to scale-up HIV VL monitoring using DBS. More field evaluations are needed to convince the Ministry of Health that DBS can effectively be used to scale-up HIV VL monitoring. The aim of the present study is to evaluate the sensitivity and specificity of HIV VL measurement using the cobas® plasma separation card (PSC) against plasma at the threshold of 1000 copies/mL (threshold currently used to define failure in Vietnam, following the WHO guidelines).
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Blood sampling | blood samples from venepuncture (10mL) |
Timeline
- Start date
- 2022-10-05
- Primary completion
- 2023-10-30
- Completion
- 2023-10-30
- First posted
- 2021-03-12
- Last updated
- 2024-03-06
Locations
2 sites across 1 country: Vietnam
Source: ClinicalTrials.gov record NCT04794725. Inclusion in this directory is not an endorsement.