Clinical Trials Directory

Trials / Completed

CompletedNCT04765397

Different Resectoscopes Effects to Optic Nerve Sheath Diameter

The Effect of Bipolar and Monopolar Resectoscope Use on Optic Nerve Diameter in Transurethral Resection Procedures Under Spinal Anesthesia

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
80 (actual)
Sponsor
Bursa Yuksek Ihtisas Training and Research Hospital · Other Government
Sex
All
Age
50 Years – 80 Years
Healthy volunteers
Accepted

Summary

In this study, in patients with benign prostatic hypertrophy, monopolar and transurethral prostate using bipolar techniques in resection; serum electrolytes in the perioperative period, osmolarity can occur in hemodynamic parameters the effect of changes on optic nerve diameter by ultrasonography.

Detailed description

This study is for TURP operation for Benign Prostate Hypertrophy patients. When patient comes to the operating room, routine preparations will be made. Haemodynamic parameters and over-the-eye with Optic nerve diameter will be checked with ultrasound before and 10 minutes after spinal anesthesia. Monopolar for patients according to the preference of the surgical team resectoscope technique or bipolar resectoscope technique will be applied. During the operation Blood pressure, pulse minute the number of irrigation solutions used and the amount of intravenously administered serum, operation time will be saved. Optic nerve sheath diameter after the operation would be checked again. intraoperative and postoperative complications in the waking room (respiratory distress, hypotension, hypertension, bradycardia, tachycardia, vomiting, headache, restlessness, seizure, arrhythmia, vision disorder) will be recorded.

Conditions

Interventions

TypeNameDescription
PROCEDUREEffect of different resectoscope fluids on optic nerve diameter measured by ultrasoundDuring the operation Blood pressure, pulse minute the number of irrigation solutions used, and intravenous serum amounts, operation time will be saved. If there is an abnormal parameters or increased optic nerve sheath surgical team will be informed.

Timeline

Start date
2018-07-20
Primary completion
2018-12-20
Completion
2019-03-15
First posted
2021-02-21
Last updated
2021-02-21

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT04765397. Inclusion in this directory is not an endorsement.

Different Resectoscopes Effects to Optic Nerve Sheath Diameter (NCT04765397) · Clinical Trials Directory