Observational Study of the Use of DBLG1 System in Real Life

Status
Recruiting
Phase
Study type
Observational
Enrollment
348 (estimated)
Sponsor
Diabeloop · Industry
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

This study will be conducted on human subjects and is observational, prospective and uncontrolled, defined as a category 3 according to the Jardé Law (RIPH3). It is a national and multicentric study. Enrolled patients are Type 1 Diabetes (T1D) patients who receive the DBLG1 System (CE marked medical device) to be treated. Patients have their regular visits with their own clinician. No change from their usual care must and will be done, including trainings and treatment. At the end of the study, patients will keep their system for their usual care and will continue having usual follow-up visits with their clinician. Data related to their glycemia, complications and quality of life will be collected for 1 year from the beginning of their treatment. A comparison with data collected during the 2 weeks of run-in period, prior to the activation of loop mode, is planned. In case the run-in phase lasts longer than 2 weeks, data collected from the two last weeks only will be kept for analysis and comparison. The study is completed when all patients have their "end of study" file completed in the electronic Case Report Form (eCRF).

Detailed description

The study is designed to address the specific requirements from National Commission for the Evaluation of Medical Devices and Health Technologies (CNEDiMTS) and to complete data obtained up to now, with a larger cohort and in real life settings. In order to increase variability in the profiles of patients included and to be as representative as possible of all eligible patients, 20 centers will participate in the study, both private and public, with a mix of university and regional centers and 348 patients will be included consecutively. The inclusion period lasts 6 months and each patient will be included in the study for a period of 2 weeks of run-in and 1 year of treatment. An inclusion period of 6 months is enough according to investigation site data and estimation of inclusion over 6 months (detailed in part Healthcare professional and investigation centers recruitment). This study is observational. Patients included follow their usual medical care and will only be asked for the specific need of the study to answer two questionnaires (at the beginning and at the end of the study) and give their HbA1c results performed in their current medical follow-up. As it is a post-registration study, medical devices are provided to patients on medical prescription by healthcare providers, which have signed a distribution agreement with and have been trained by Diabeloop. Patients have their system for 4 a maximum of 4 years (life duration of the medical device (DBLG1 System)). Patients follow-up visits are not mandatory and no frequency is imposed. Investigators, according to their habits, have follow-up visits corresponding to what they usually propose to patients having a new treatment. During the whole study and apart from scheduled visits (inclusion, beginning of run-in, beginning of treatment , enf of study), each patient may contact his/her clinician investigator in case of issue he/she judges as serious, for questions, etc. In that case, the clinician may program a visit with the patient and deal with adverse events. Phone calls are recorded in Case Report Form (CRF), as well as on-site visits. Note: with Yourloops; investigators may follow the state of their patients, regarding the time in range, mean glycemia value etc. Based on this, they may require a visit at their convenience with the patient in order to change parameters of the system, discuss adverse events, etc. Objectives are the following To evaluate improvement in blood glucose control with use of DBLG1 System after one year in real life. To evaluate details of glycemic control improvement, safety and adverse events due to the DBLG1 System, evolution of quality of life after one year in real life and healthcare professional support. Study endpoints Improvement of the time in glycemic range 70 - 180 mg/dL, in percentage, on 24hours and nighttime. HbA1c Mean CGM glucose - on 24hours and nighttime Time in 70 - 140 mg/dL range on 24hours and nighttime only Time in hypoglycemia (under 70 mg/dL, 60 mg/dL and 50 mg/dL) - on 24hours and nighttime Time in hyperglycemia (above 180 mg/dL, 250 mg/dL and 300 mg/dL) - on 24hours and nighttime Percentage of time using activated loop mode vs. deactivated loop mode Standard Deviation (SD) and Coefficient of variation (CV) of Continuous Glucose Monitoring (CGM) values on 24hours and nighttime Number and type of adverse events Overall and diabetic-specific quality of life Quantification of the healthcare professional support required An descriptive interim analysis will be made on the first 100 enrolled patients after 6 months of use of the DBLG1.

Conditions

Interventions

TypeNameDescription
DEVICEDBLG1 SystemUse of DBLG1 System in real life condition

Timeline

Start date
2021-05-17
Primary completion
2025-07-01
Completion
2026-01-01
First posted
2021-02-11
Last updated
2024-05-07

Locations

20 sites across 1 country: France