Trials / Unknown
UnknownNCT04738604
Clinical Performance and Wear Resistance of Two Nano Ceramic Resin Composite in Class I Cavities
Clinical Performance and Wear Resistance of Two Nano Ceramic Resin Composite in Class I Cavities: A Randomized Clinical Trial
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 28 (estimated)
- Sponsor
- Cairo University · Academic / Other
- Sex
- All
- Age
- 20 Years – 54 Years
- Healthy volunteers
- Accepted
Summary
in patients with Class I Cavities, will the use of Zenit Nano Ceramic Composite restorations have similar clinical performance to conventional Ceram-X Nano Ceramic Composite restorations, evaluation of restorations will be done at baseline, six, and twelve months using Modified USPHS Ryge criteria.
Detailed description
The study will be conducted in the clinic of Conservative Dentistry Department, Faculty of Dentistry, Cairo University; the operator in charge samah mohamed bahig, The subjects fulfilling the eligibility criteria of the trial will be selected from the regular attendees at the clinic of Conservative Dentistry Department, Faculty of Dentistry, Cairo University. Patient examination will be done including medical history, dental history, extra-oral examination and intraoral examination. A periapical radiograph will be taken prior to restorative procedures to assess the degree of approximation of caries to pulp, intactness of lamina dura and/or presence of any periapical radiolucency to exclude the case. The field of operation will be isolated with the application of a rubber dam if possible. Otherwise, cotton rolls and the saliva ejector will be used for moisture control. For cavity preparation, local anesthetic (MepecaineL, Alexandria Company, Egypt) solution will be administrated to control patient discomfort during the procedure. The cavities will be prepared by using cylindrical #314 (Komet®, Germany) in a high speed handpiece (Sirona, Germany) rotating at high speed with copious coolant. Remaining soft caries -if present- will be removed using sharp excavator (Maillefer, Dentsuply, Switzerland).After the cavity preparation is finished, it will be thoroughly air-water cleaned. The bonding system; the Prime and Bond universal adhesive (Dentsply De Trey GmbH, Konstanz, Germany) will be applied according to the following instructions recommended by the manufacturer and rubbed for 20 seconds then blown with a gentle air blow for 5 seconds to evaporate the solvent and then light curing for 10 seconds using LED light curing unit (\>700 mW/cm2).The prepared cavities will be restored with Zenit Nano Ceramic Composite (PRESIDENT DENTAL, GmbH, Munich, Germany) will be applied with incremental placement technique (maximum: 2-mm layer). Increments will be light curing for 40 seconds according to manufacturer's instructions. and for the control group cavities will be restored withCeram•X (Dentsply De Trey GmbH, Konstanz, Germany) with incremental placement technique (maximum: 2-mm layer). Increments will be light cured for 20 seconds according to manufacturer's instructions.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | Ceram•X (Dentsply De Trey GmbH, Konstanz, Germany | The prepared cavities will be restored with Ceram•X (Dentsply De Trey GmbH, Konstanz, Germany) with incremental placement technique (maximum: 2-mm layer). Increments will be light curing for 20 seconds according to manufacturer's instructions. |
| OTHER | Zenit Nano Ceramic Composite (PRESIDENT DENTAL, GmbH, Munich, Germany) | The prepared cavities will be restored with Zenit Nano Ceramic Composite (PRESIDENT DENTAL, GmbH, Munich, Germany) with incremental placement technique (maximum: 2-mm layer). Increments will be light curing for 40 seconds according to manufacturer's instructions. |
Timeline
- Start date
- 2022-03-01
- Primary completion
- 2023-01-01
- Completion
- 2023-02-01
- First posted
- 2021-02-04
- Last updated
- 2021-08-31
Source: ClinicalTrials.gov record NCT04738604. Inclusion in this directory is not an endorsement.