Clinical Trials Directory

Trials / Withdrawn

WithdrawnNCT04699552

Effect of Laser Settings on Postoperative Voiding Symptoms in Patients Undergoing Holmium Laser Enucleation of the Prostate

Effect of Laser Settings on Postoperative Voiding Symptoms in Patients Undergoing Holmium Laser Enucleation of the Prostate: A Randomized Prospective Trial

Status
Withdrawn
Phase
N/A
Study type
Interventional
Enrollment
0 (actual)
Sponsor
Indiana University · Academic / Other
Sex
Male
Age
18 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to evaluate the safety and outcomes, such as postoperative dysuria (pain during urination), urgency (frequent need to urinate) and urinary incontinence (leaking urine or inability to hold urine), of 3 different HoLEP laser settings.

Detailed description

Study subjects will be identified by the clinical team or study coordinator either at the time surgery is scheduled or by review of the surgery schedule. Each subject will be screened for inclusion/exclusion criteria by reviewing the chart. If inclusion/exclusion criteria are met, the patient will be approached by a member of the research team for enrollment into the study. The patient must consent to participate by reviewing a study-specific, IRB-approved informed consent form before any study data is collected. After informed consent has been obtained, a complete medical history including a detailed urologic history will be obtained prior to the HoLEP procedure. Standard pre-operative laboratory tests will be obtained, including a complete blood count, basic metabolic panel and urine culture. Pre-operative, intra-operative and post-operative management of the patients included in this study will not differ from routine HoLEP treatment options described in the literature and practiced at our center. All laser settings examined are currently utilized. A complete description of the HoLEP procedure at our institution has previously been described15. Briefly, a 550um Lumenis MOSES fiber will be utilized. A 120W Holmium:YAG laser made by Lumenis will be used. Operatively, the time (minutes) for resection of the tissue will be recorded as "enucleation time". Once enucleation of the tissue has been completed, the time (in minutes) for complete removal of the enucleated tissue will be recorded as "morcellation time". Enucleated tissue can be removed by any means determined necessary by the surgeon, i.e. he/she may use the holmium laser or graspers in combination with the morcellator. Enucleation is typically performed in a stepwise fashion with an initial groove at the 5 and 7 o'clock position, followed by enucleation of the median lobe. The enucleation of the lateral lobes occurs in a bottom up approach. At times depending on patient anatomy an intraoperative decision by the treating surgeon may result in an early apical release. The power settings of 2J of energy will be consistent between the three treatment arms. The frequency will differ from 20Hz, 40Hz and 60Hz between the three treatment arms. After enucleation, hemostasis is performed at a setting of 1J and 20 Hz with a widened pulse width for standard HoLEPs. For patients with a high median bar of bladder neck tissue, a single incision at the bladder neck is made at 6 o'clock. Total amount of laser energy utilized for the procedure will also be recorded. Note will be made of concurrent procedures done at the time of HoLEP including: bladder calculi managed with cystolithopaxy or upper urinary tract calculi management. Postoperative, patients will be provided with daily Twilio assessments of their postoperative dysuria, urgency and urgency urinary incontinence (as defined above) until it has resolved and remained symptom free x 3 consecutive days. Follow up Twilio assessments at 1month, 3month and 6months will be performed. Patients will concurrently follow up for standard postoperative face-to-face or virtual visit evaluations with their surgical team at 3months.

Conditions

Interventions

TypeNameDescription
DEVICE120W Lumenis Holmium:YAG laser 20J120W Lumenis Holmium:YAG laser 20J
DEVICE120W Lumenis Holmium:YAG laser 40 J120W Lumenis Holmium:YAG laser 40J
DEVICE120W Lumenis Holmium:YAG laser 60 J120W Lumenis Holmium:YAG laser 60J

Timeline

Start date
2020-12-01
Primary completion
2021-07-01
Completion
2021-12-01
First posted
2021-01-07
Last updated
2021-01-07

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT04699552. Inclusion in this directory is not an endorsement.