Clinical Trials Directory

Trials / Recruiting

RecruitingNCT04646083

Depth of Maximal Ileal Insertion During Retrograde Enteroscopy With TTS Balloon

Depth of Maximal Insertion During Retrograde Enteroscopy Using Colonoscopy With Through-the-scope Balloon Enteroscopy (NaviAid) Compared With Using the Standard Colonoscope Alone

Status
Recruiting
Phase
Study type
Observational
Enrollment
100 (estimated)
Sponsor
Texas Tech University Health Sciences Center, El Paso · Academic / Other
Sex
All
Age
18 Years – 90 Years
Healthy volunteers
Not accepted

Summary

Diagnostic modalities for the evaluation of small bowel pathology include video capsule endoscopy (VCE), antegrade and retrograde device-assisted enteroscopy, CT and MR enterography (1). Despite VCE being the first-line evaluation modality, it lacks interventional capability. Deep enteroscopy (DE) allows tissue sampling and other therapeutic interventions with real-time endoscopic assessment. DE is usually performed with specific endoscopes (balloon-assisted device or spiral overtube) making it time consuming and there is limited availability since special instruments and accessories are required.(1,2) The through-the-scope (TTS) balloon system consists of a balloon catheter designed for anchoring in the small bowel, inserted through the instrument channel of a standard colonoscope.(3) The catheter is advanced, the balloon is inflated and anchored in the small intestine and the endoscope slides over the guiding catheter to the inflated balloon. The most common indications for DE are obscure GI bleeding, iron deficiency anemia, abnormal capsule endoscopy and chronic diarrhea. As compared to spiral, single-or double-balloon enteroscopy, TTS (NaviAid, SMART Medical Systems Ltd, Ra'anana, Israel) is a simpler technique, which requires less investment in infrastructure. The balloon catheter is advanced blindly in front of a standard adult colonoscope as it bends around the curves of the small bowel. To prevent perforation/trauma the catheter is fitted with a soft silicone tip which easily bends under pressure. Insertion depth can be calculated during the withdrawal of the enteroscope. The Aim of the study: To compare the depth of maximal ileal insertion between through-the-scope balloon enteroscopy (NaviAid) with enteroscopy using the adult colonoscope (Olympus CF-190) alone, in the same patient, in a prospective cohort at University Medical Center of El Paso, Texas.

Detailed description

The Aim of the study: To compare the depth of maximal ileal insertion between through-the-scope balloon enteroscopy (NaviAid) with enteroscopy using the adult colonoscope (Olympus CF-190) alone, in the same patient, in a prospective cohort from August 1, 2020 to July 31, 2023 at University Medical Center of El Paso, Texas. Depth of insertion is correlated with diagnostic yield, meaning that we would like to ascertain if the use of the colonoscope with NaviAid will result in greater depth of insertion and potentially more findings of small bowel abnormalities than using a colonoscope alone. It is assumed that this is the case, but we want to show it and quantify it. HYPOTHESIS: The depth of ileal insertion is greater with the use of through-the-scope balloon enteroscopy (NaviAid) when compared with enteroscopy using the standard adult colonoscope (Olympus CF-190) alone. OBJECTIVE: To compare the depth of maximal ileal insertion between through-the-scope balloon enteroscopy (NaviAid) with the adult colonoscope (Olympus CF-190) alone, in the same patient, in a prospective cohort at University Medical Center of El Paso, Texas.

Conditions

Timeline

Start date
2021-01-14
Primary completion
2025-12-31
Completion
2025-12-31
First posted
2020-11-27
Last updated
2025-06-18

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT04646083. Inclusion in this directory is not an endorsement.