Clinical Trials Directory

Trials / Completed

CompletedNCT04633746

Plasma Endostatin Predicts Outcome of Septic AKI

Validation of Plasma Endostatin for Predicting Renal Outcome From Acute Kidney Injury Induced by Sepsis

Status
Completed
Phase
Study type
Observational
Enrollment
40 (actual)
Sponsor
Cairo University · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

Introduction: Acute kidney injury (AKI) occurs up to 50% of patients admitted to intensive care unit. Plasma Endostatin, released from basement membrane of Bowman's capsule, rises early during AKI. Aim of Work: To investigate the role of the plasma endostatin in the outcome prediction (renal recovery, ICU stay, mortality) of acute kidney injury in patients with sepsis. Methods: a prospective, observational single center study on 40 patients with Sepsis at the Critical Care Department, Cairo University hospitals between March 2019 and November 2019. Serum plasma endostatin was measured at the day of admission \& every 48hrs (3 samples). APACHE II, SOFA scores were calculated. Forced diuresis was used if indicated.

Detailed description

The study was conducted on 40 patients with sepsis who admitted in the Critical Care department of Cairo University. The sepsis is identified according to surviving sepsis campaign guidelines with use of SOFA score to establish the diagnosis. The patients divided into 2 groups the first group included 25 patients who developed AKI as defined by KDIGO guidelines and the other group included 15 patients as a control group. The Plasma Endostatin level is sampled in the first 24 hours of diagnosis of AKI, the estimation of plasma Endostatin level done by ELISA technique. The results were presented in form of: descriptive, analytical and comparative data between the groups of study. It was found that the patients with higher levels of plasma endostatin had a higher incidence of recovery from AKI and higher incidence of 28 days survival, while the patients with lower levels of plasma Endostatin below the determined Cut-off value have increased incidence of RRT . Also that the patients with higher levels of plasma Endostatin levels were less labile to mechanical ventilation and had a higher incidence of weaning of vasopressors in comparison of the other group of lower levels of plasma Endostatin. Plasma Endostatin levels have no difference between the AKI group and sepsis group which may need further investigations to determine its role in sepsis. so that, the plasma Endostatin can be used as a marker of recovery from AKI.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTmeasuring plasma Endostatin levelmeasuring plasma Endostatin level at the time of admission then after 48hrs and 96 hours

Timeline

Start date
2019-01-20
Primary completion
2020-06-30
Completion
2020-08-31
First posted
2020-11-18
Last updated
2020-11-18

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT04633746. Inclusion in this directory is not an endorsement.