Clinical Trials Directory

Trials / Completed

CompletedNCT04618978

Periodic Leg Movements' Diagnosis in Spinal Cord Injury: Actigraphy as an Alternative for Polysomnography?

Periodic Leg Movement's Diagnosis in Spinal Cord Injury: Actigraphy as an Alternative for Polysomnography?

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
160 (actual)
Sponsor
Assistance Publique - Hôpitaux de Paris · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Periodic Limb Movements during Sleep (PLMs) are episodes of repetitive, stereotypical, hallux or foot movements. They could induce sleep disturbance, fatigue, daytime sleepiness and impaired quality of life but also increased cardiovascular risk by rising heart rate and blood pressure at night. Gold standard for PLMs diagnosis is based on electromyographic recording of tibialis anterior muscle during full night polysomnography (PSG). PLMs prevalence is higher in patients with spinal cord injury (SCI) possibly due to a loss of encephalic inhibition on a spinal motion generator. In these patients, PLMs can also be wrongly considered as spasms sometimes leading to the unjustified implantation of an intrathecal Lioresal pump. In the general population, drug treatments for PLMs, particularly dopamine agonists, limit the impact of these abnormal movements on sleep fragmentation, daytime alertness and quality of life. Underdiagnosed PLMs in SCI patients can lead to exacerbate cognitive, mood and painful disorders due to the close interaction between sleep disorders and neurocognitive, psychological and painful manifestations. PLMs appropriate diagnosis appeared mandatory in those patients but accessibility and delayed availability remain challenging. In addition, sleep laboratories are often unable to accommodate with SCI patients. In this context, actigraphy, an easy-to-use, cheaper and easily renewable diagnostic tool would be interesting. In the general population, sensitivity to diagnose PLMs was between 0.79 and 1 and specificity between 0.6 and 0.83. Due to lower limbs impairment, increased specificity is expected SCI patients (decrease voluntary activity). The new generation of actigraph (MotionWatchR) could have better characteristics thanks to the development of a specific software which integrate both lower limbs in the same analysis. As primary objective, this prospective monocentric study aims to evaluate the performances of lower limbs actigraphy for PLMs diagnosis versus gold standard.

Detailed description

As secondary objectives, the study aims to: * Estimate positive and negative predictive values; * Identify the diagnostic threshold of PLMs index with actigraphy; * Study concordance between actigraphy and polysomnography to detect lower limbs movements; * Evaluate reproducibility between 2 readers and with the new PLMs software; * Study actigraphy reproducibility for this indication over 3 consecutive nights in the same patients (ancillary study); * Compare diagnostic performance according to SCI completeness (AIS-A vs AIS-B, C, D) and underlying pathology (MS, SCI); * Compare installation and interpretation times between actigraphy and PSG. PLMs appropriate diagnosis appeared mandatory in SCI patients however the accessibility and the delay of availability remain challenging for severe SCI complications in care management. The study team hypothesize that actigraphy could be able to diagnose PLMs with sufficient reliability (AUC (area under the curve) around 80%) compared to the gold standard (polysomnography) in patients with spinal cord injuries. Intervention: During a scheduled night recording (polysomnography) 3 actigraphs will be added (1 on the wrist, and 1 on each foot). Equipment: MotionWatch8®, CamNtech® (marking CE Class 1 device; accord FDA (K132764)). Methods: All consecutive eligible patients followed in our tertiary care center (for whom a full night polysomnography is already scheduled) will be informed of the study and proposed to participate. After signing the informed consent form, all subjects will undergo a full-night examinations: polysomnography (already scheduled in usual care) and actigraphy (addition of 3 devices): * 1 classic actigraph on the wrist to detect light and identify inactivity periods compatible with sleep. * 2 new generation Actiwatch actigraphs (MotionWatch) placed on the feet. Polysomnography will incorporate tibialis anterior EMG recording and will be scored by one sleep specialist following American Academy of Sleep Medicine (AASM) scoring criteria. Actigraphy analysis will be provided by: * An automated software specially developed for this indication (PLMsanalysis software, camNtechR). * A nurse reading unaware of both software's and PSG results. * A second reading will be provided by a second nurse, also unaware of the result of the polysomnography. Actigraphy results will not be communicated to patients or physicians and therefore will not affect patient management. At the end of the evaluation period, each patient will be offered, if needed, treatment and follow-up in the sleep unit as in usual care. A study of actigraphy reproducibility will be carried out in a sample of 33 subjects. This study will take place over three consecutive nights during an already scheduled hospitalization (no additional hospitalization night for patients). Statistical analysis: as described in Outcome Measures.

Conditions

Interventions

TypeNameDescription
PROCEDUREPSG and actigraphy recordingGold standard: electromyographic recording of tibialis anterior muscle during full night polysomnography (PSG). The new generation actigraphs devices Actiwatch will be combined to PSG as a screening tool: MotionWatch will be placed on the dorsum of feet to record).

Timeline

Start date
2021-02-25
Primary completion
2024-07-04
Completion
2025-01-17
First posted
2020-11-06
Last updated
2025-02-11

Locations

1 site across 1 country: France

Source: ClinicalTrials.gov record NCT04618978. Inclusion in this directory is not an endorsement.