Clinical Trials Directory

Trials / Unknown

UnknownNCT04594629

PGI2 Versus Nitroglycerine for Management of Pulmonary Hypertension After Valve Surgeries

Efficacy of Nebulized PGI2 Versus Nebulized Nitroglycerine for Management of Pulmonary Hypertension After Valve Replacement Surgeries

Status
Unknown
Phase
Phase 1
Study type
Interventional
Enrollment
120 (estimated)
Sponsor
Ain Shams University · Academic / Other
Sex
All
Age
54 Years – 65 Years
Healthy volunteers
Not accepted

Summary

This study was conducted in 120 patients aged from 54-65 years scheduled for elective valve replacement surgeries. Patients were randomly allocated to nitro glycerine or PGI2 groups. Patients of nitro glycerine group received nebulized nitro glycerine at a rate of 2.5-5 mcg/kg/min (5 mg, 1 mg/ml) over 10 minutes by ultrasonic nebuliser. Patients of PGI2 group received nebulized PGI2 (epoprostenol), 20000 ng/ml (20000 ng/ml in 60 ml syringe was attached to an intravenous pump which delivers a titrating rate of 8 ml/h . The primary outcome was mean pulmonary artery pressure. The secondary outcomes included mean arterial blood pressure (MAP) (mmHg), PaO2/FiO2 ratio, cardiac index (CI) (l/min/m2) right ventricular ejection fraction (RVEF), central venous pressure(CVP) , 30-day mortality rate and the incidence of complications such as facial flushing, hypotension and re-exploration for bleeding.

Detailed description

Postoperative pulmonary hypertension (PHT) is the most challenging complication of valvular heart disease about 73% of the patients particularly in those posted for mitral valve replacement surgery Methods This prospective study was conducted in 120 patients aged from 54-65 years scheduled for elective valve replacement surgeries. Patients were randomly allocated to either nitro glycerine or PGI2 groups. Patients of nitro glycerine group received nebulized nitro glycerine (its starting concentration was 200 mcg/ml); nitro glycerine was delivered at a rate of 2.5-5 mcg/kg/min (5 mg, 1 mg/ml) over 10 minutes by ultrasonic nebuliser connected to the inspiratory limb of the breathing circuit. Patients of PGI2 group received nebulized PGI2 (epoprostenol), 20000 ng/ml (20000 ng/ml in 60 ml syringe was attached to an intravenous pump which delivers a titrating rate of 8 ml/h to the nebulizer compartment. The primary outcome was mean pulmonary artery pressure. The secondary outcomes included mean arterial blood pressure (MAP) (mmHg), PaO2/FiO2 ratio, cardiac index (CI) (l/min/m2) right ventricular ejection fraction (RVEF), central venous pressure(CVP) measured at the end of cardiopulmonary bypass then 30 minutes after start of treatment then 4 hours after start of treatment, 30-day mortality rate and the incidence of complications such as facial flushing, hypotension and re-exploration for bleeding.

Conditions

Interventions

TypeNameDescription
DRUGNitroglycerinPatients of nitroglycerine group received nebulized nitro glycerine (a vial contains 50 mg nitroclycerine ), its starting concentration was 200 mcg/ml with nitro glycerine was delivered at 2.5-5 mcg/kg/min (5 mg, 1 mg/ml) over 10 minutes by ultrasonic nebuliser connected to the inspiratory limb of the breathing circuit
DRUGPGI2Patients of PGI2 group received nebulized PGI2 (epoprostenol), 20000 ng/ml (Flolan; Glaxo Wellcome Inc, Research Triangle Park, NC) (60 ml syringe of PGI2 with concentration 20000 ng/ml was attached to an intravenous pump which delivers a titrating rate of 8 ml/h to the nebulizer compartment (MiniHEART nebulizer; Westmed, Tucson, Ariz) fixed to the inspiratory limb of the breathing circuit or to the face mask with venturi accessory for sprinkling. The nebulizer was filled with 15 ml PGI2 with nebulized oxygen flow rate 3 litres

Timeline

Start date
2020-11-01
Primary completion
2021-05-01
Completion
2021-06-01
First posted
2020-10-20
Last updated
2020-10-20

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT04594629. Inclusion in this directory is not an endorsement.