Is the Dynamic of the Pelvic Bone Altered After a Total Hip Replacement ?

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
53 (estimated)
Sponsor
University Hospital, Brest · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Total hip replacement is one of the most common surgical procedure in France. In 2010, an estimated 147 513 total hip procedures were performed. This number is constantly increasing. Although it is common, it can lead to many complications. The intra-prosthetic luxation is the second one after aseptic loosening. The luxation risk is multifactorial and depends on the relative orientation of femoral et acetabular components. This orientation is influenced by statics and dynamics parameters. So far, the literature shows that only static parameters are considered by surgeons. Thus, in reference to Lewinneck publication, which states that the luxation risk is lower if the cup is oriented with 15° +/- 10° of anteversion and 40°+/- 10° of inclination with respect to the anterior pelvic plan (APP). Defined by the two anterosuperior iliacs spines and pubic symphysis. However, this approach is only static and do not take into account the variations of pelvic plan orientation during everyday life. To consider these variations of pelvic inclination, it is possible to measure the angle between APP and the horizontal (in lying position) or the vertical (in standing position) plan. Several devices allow the measure of pelvic inclination but they all have important limits (EOS radiography, scanner or navigation). A new device has been developed in Brest to measure this inclination in several positions of the daily life.This software has already been tested in healthy volunteers and results demonstrate an excellent accuracy and reproducibility. The goal of this study is to described the dynamic of the pelvic bone thanks to this ultrasound based device, and to assess the amount of variation induced by hip replacement procedures.

Conditions

Interventions

TypeNameDescription
OTHERPelvic inclination measurementUltra-sound based measurements of the pelvic inclination lying, standing and seating position. EOX X-ray in seating position.

Timeline

Start date
2021-02-02
Primary completion
2023-02-02
Completion
2023-08-02
First posted
2020-10-14
Last updated
2022-01-11