Clinical Trials Directory

Trials / Completed

CompletedNCT04586855

Ultrasound Imaging of the Larynx and Diaphragm During NIV and Cough Assist

Can Ultrasound Imaging of Both Upper Airways and Diaphragm be Used to Guide Efficacy on Non-invasive Ventilation and Cough Assist

Status
Completed
Phase
Study type
Observational
Enrollment
30 (actual)
Sponsor
Haukeland University Hospital · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

The study examines if diagnostic ultrasound imaging of larynx and diaphragm can be as accurate as transnasal fiberoptic laryngoscopy in visualizing the larynx during NIV and Mechanically Assisted Cough interventions.

Detailed description

Transnasal fiberoptic laryngoscopy (TFL) is gold standard for visualising the larynx. TFL has been used to visualize the laryngeal response patterns during non-invasive therapeutic interventions, as during Mechanically Assisted Cough in patients with Amyotrophic Lateral Sclerosis. The examinations revealed that the larynx adducted during the application of positive pressures, which restricted the airflow and reduced the efficacy of the treatment. The higher treatment pressures resulted in ineffective interventions as a result of the adducted vocal cords obstructing flow. This knowledge has changed the treatment approach for patients with possible upper airway instability by individualizing the treatment pressures and flow due to laryngeal responses. TFL may cause slight discomfort when placing the laryngoscope. Diagnostic ultrasound is non-invasive easily applicable technique that has gained increasing popularity in diagnosing cardiopulmonary and laryngeal conditions during the recent times. The aim of the study is to investigate whether the diagnostic ultrasound of the larynx can be as accurate as TFL during Mechanically Assisted Cough and Non-Invasive Ventilation (NIV). The present study will include healthy participants. Hypothesis is that diagnostic ultrasound of larynx can provide clinical valuable information of the laryngeal response patterns during Mechanically Assisted Cough and NIV. The aims of the study are: * To evaluate the feasibility of diagnostic ultrasound imaging of the larynx, and to compare to the gold standard of TFL used during ongoing NIV and Mechanically Assisted Cough in healthy subjects. * To evaluate the feasibility of ultrasound imaging if the diaphragm during ongoing NIV and Mechanically Assisted Cough in healthy subjects.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTDiagnostic UltrasoundTo investigate if Ultrasound imaging can visualize the larynx during NIV and Cough Assist, and be as accurate as laryngoscopy
DIAGNOSTIC_TESTTransnasal Fiberoptic LaryngoscopyTo investigate if Ultrasound imaging can visualize the larynx during NIV and Cough Assist, and be as accurate as laryngoscopy

Timeline

Start date
2022-01-01
Primary completion
2022-04-07
Completion
2022-04-07
First posted
2020-10-14
Last updated
2025-03-24

Locations

1 site across 1 country: Norway

Source: ClinicalTrials.gov record NCT04586855. Inclusion in this directory is not an endorsement.