Clinical Trials Directory

Trials / Completed

CompletedNCT04566185

Evaluation of the Predictive Value of 18F-fluorodeoxyglucose Positron Emission Tomography and Brain Perfusion Computed Tomography for the Efficacy of Anti-angiogenic Therapy (Bevacizumab) in Recurrent Glioblastoma

Evaluation of the Value of 18F-fluorodeoxyglucose Positron Emission Tomography (FDG PET) and Brain Perfusion Computed Tomography (CT Perfusion) for Predicting the Efficacy of Anti-angiogenic Therapy (Bevacizumab) in Patients With Recurrent Glioblastoma

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
14 (actual)
Sponsor
Centre Hospitalier Universitaire de Nīmes · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

In this pilot study, the study evaluators will evaluate the ability of positron emission tomography (PET) with 18F-fluorodeoxyglucose (FDG PET) and the computed tomography (CT) perfusion scanner, individually and combined, to predict the effectiveness of anti-angiogenic treatment.

Conditions

Interventions

TypeNameDescription
OTHERFDG PETIV application of F Dopa, 2 MBq per Kg, with a scout view (angle of view 90 °, 120 kV, 30 mAs), then an X-ray scan is performed for the attenuation correction ( 120 kV - 5mAs - pitch 0.531 - thickness // increment: 3.75mm//3.27mm -QAC filter - DFOV 25). PET acquisition: static in 3D mode for 20 minutes, 8 minutes after the injection of 18 F Dopa, the axial field of view is 25, the matrix in 256 x 256. After OSEM reconstruction 6 iterations and 24 subsets, with correction of attenuation and diffusion, then Gaussian filter of frequency 4, 47 contiguous axial sections of 3.26 mm are obtained.
OTHERCT scanLocalization propeller without injection: 120kV - mA regulation (Noise Index 15) - pitch 0.969 - thickness // increment: 5mm // 5mm - Soft filter - Asir 60% - DFOV 25. Acquisition begins 5 seconds after the start of the injection of 60 ml of contrast product (VISIPAQUE) at 4 cc / second without (acquisition characteristics: 80 kV - 100 mAs -- thickness: 5mm // 8 images / rotation - STD filter - Asir 50% display field of view (DFOV) 25 - phase1: 5s then phase2 15s). Diagnostic quality CT: 120kV - Regulation of mA (Noise Index 15) - pitch 0.531 - thickness // increment: 1.25 // 0.625mm - Soft filter - Asir 60% - DFOV 25.
OTHERMagnetic resonance imaging (MRI)If the examination is performed on the SIEMENS SKYRA 3T device: 32 channel head coil antenna, if on the PHILIPPS INGENIA 1.5 T device: DStream HeadSpine Coil antenna. The sequence begins with an axial, coronal and sagittal "Survey" topogram, lasting 1 minute. Then axial sequence T1, Axial T2 \*, Axial cerebral perfusion (Injection of gadolinium (0.1 mmol / kg, 5 cc / second), coronal T2, Axial T2 Flair, Axial DWI b100, Axial 3D T1 gadolinium

Timeline

Start date
2020-12-16
Primary completion
2023-06-27
Completion
2023-06-27
First posted
2020-09-28
Last updated
2025-12-18

Locations

1 site across 1 country: France

Source: ClinicalTrials.gov record NCT04566185. Inclusion in this directory is not an endorsement.

Evaluation of the Predictive Value of 18F-fluorodeoxyglucose Positron Emission Tomography and Brain Perfusion Computed T (NCT04566185) · Clinical Trials Directory