Clinical Trials Directory

Trials / Unknown

UnknownNCT04549714

Quantitative Ablation of Pulmonary Vein Vestibule in Paroxysmal Atrial Fibrillation.

A Prospective,Single Center, Randomized Controlled Trial of Quantitative Ablation of Pulmonary Vein Vestibule in Patients With Paroxysmal Atrial Fibrillation..

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
90 (estimated)
Sponsor
Yuehui Yin · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

The purpose of this trial is to explore the optimal AI value for isolating the pulmonary veins and achieving left ventricular apex and mitral isthmus block. Patients with atrial fibrillation who are scheduled to undergo catheter ablation will be randomized to different groups, then every group receive circumferential pulmonary vein isolation with different AI values. The relevant indicators such as the proportion of pulmonary vein single-circle isolation, operation time, the incidence of complications, and the proportion of recurrence of atrial fibrillation and other atrial arrhythmias after 1 year were collected.

Detailed description

This is a prospective, single-center, randomized controlled trial. In this part,a total of 90 patients with paroxysmal atrial fibrillation who are scheduled for catheter ablation were randomly divided into 3 groups, 30 patients in each group. For the first group, the AI target value for the front wall and the top wall is 550, and the rear wall and the lower wall are 400. For the second group, the AI target values for the front wall and the top wall are 500, the rear wall and the lower wall are 350. For the third group, the AI target values for the front wall and top wall are 450, the rear wall and the lower wall are 300. The pressure value at each point is 5-15 g, and the distance between adjacent ablation points is less than 5 mm. The relevant indicators such as single-circle isolation rate of the pulmonary vein, operation time, the left atrial operation time, and the supplemental ablation site are recoded. The incidence of intraoperative and postoperative complications such as stroke, pericardial tamponade and steam pop during ablation are observed. Dynamic electrocardiography is performed during the follow-up period to evaluate the proportion of sinus rhythm within 1 year.

Conditions

Interventions

TypeNameDescription
PROCEDUREHigh AI in paroxysmal atrial fibrillationPatients with paroxysmal AF will receive pulmonary vein vestibule ablation with high AI value, the AI target value for the front wall and the top wall is 550, and the rear wall and the lower wall are 400.
PROCEDUREMiddle AI in paroxysmal atrial fibrillationPatients with paroxysmal AF will receive pulmonary vein vestibule ablation with middle AI value, the AI target value for the front wall and the top wall is 500, and the rear wall and the lower wall are 350.
PROCEDURELow AI in paroxysmal atrial fibrillationPatients with paroxysmal AF will receive pulmonary vein vestibule ablation with low AI value, the AI target value for the front wall and the top wall is 450, and the rear wall and the lower wall are 300.

Timeline

Start date
2019-06-07
Primary completion
2020-12-31
Completion
2021-08-31
First posted
2020-09-16
Last updated
2020-09-16

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT04549714. Inclusion in this directory is not an endorsement.

Quantitative Ablation of Pulmonary Vein Vestibule in Paroxysmal Atrial Fibrillation. (NCT04549714) · Clinical Trials Directory