Trials / Completed
CompletedNCT04495634
Evaluation of a Carbon Nanotube Enabled Solid-State Head CT
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 17 (actual)
- Sponsor
- University of North Carolina, Chapel Hill · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Purpose: The purpose of this study is to evaluate stationary head CT (s-HCT) as a diagnostic tool in patients with known head trauma. Participants: Participants will be 50 people who have had either a head trauma or a brain bleed and have undergone a head CT in the past 24 hours or who will undergo a CT scan of the head. Procedures (methods): This investigation will be a single arm, prospective clinical trial. Participants will have one single visit, which will include the s-HCT scan. No follow-up is required. All images will be de-identified before inclusion within a reader study. The investigators will perform a reader study with physician readers comparing the acquired imaging s-HCT images and conventional head CT.
Detailed description
This investigation will be a single arm, prospective clinical trial evaluating stationary head CT (s-HCT) as a diagnostic tool in patients with known head trauma. The investigators hypothesize that a stationary head CT (s-HCT) system based on the carbon nanotube linear array x-ray source can provide diagnostic quality head CT images. Patients included in the study will be 50 people who have had either a head trauma or a brain bleed and have undergone a head CT in the past 24 hours or who will undergo a CT scan of the head.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Stationary Head CT (s-HCT) | The system consists of a total of three x-ray sources and nine x-ray detectors with an estimation of approximately 150 projection angles per slice, with less than a minute per slice reconstruction. Radiation dose will be configured as to not exceed that of a conventional head CT, or 2 mSv. The subjects will be positioned on a medical procedure table that will move the subject through the scanning system at the rate of roughly 1 cm per second, during which the necessary x-ray projections will be acquired. The head will be positioned in a carbon fiber head holder from a clinical CT scanner that is secured to the table. |
Timeline
- Start date
- 2022-10-12
- Primary completion
- 2023-09-13
- Completion
- 2023-09-13
- First posted
- 2020-08-03
- Last updated
- 2024-10-08
- Results posted
- 2024-10-08
Locations
1 site across 1 country: United States
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT04495634. Inclusion in this directory is not an endorsement.