Clinical Trials Directory

Trials / Completed

CompletedNCT04428229

Optic Nerve Sheath Diameter in Laparoscopic Surgeries During Trendelenburg Position

The Evaluation of Optic Nerve Sheath Diameter in Patients Underwent Laparoscopic Colon and Gynecologic Surgeries During Trendelenburg Position.

Status
Completed
Phase
Study type
Observational
Enrollment
40 (actual)
Sponsor
Medipol University · Academic / Other
Sex
All
Age
18 Years – 75 Years
Healthy volunteers

Summary

It is difficult to measure the several levels of intracranial pressure during abdominal surgery, and direct monitoring with intracranial devices is often impossible. Measurement of optic nerve sheath diameter (ONSD) via ultrasonography has been developed as an alternative method for evaluating intracranial pressure. Increased intracranial pressure may cause in expanding of the optic nerve sheath and may increase the diameter. Therefore, measuring the diameter of the optic nerve sheath via ultrasonography is considered as a non-invasive, easy-to-apply and reliable method to evaluate intracranial pressure.

Detailed description

The peritoneum is inflated with carbon dioxide (insufflation) and head-down position is performed (Trendelenburg) during laparoscopic colon and gynecologic surgeries. Intracranial pressure (ICP) may be affected by positive intraabdominal pressure due to pneumoperitoneum. The Trendelenburg position (usually at a degree of 25-400) causes increasing in the pressure of cerebrospinal fluid during surgery. Therefore, cerebral edema and an increasing in ICP may occur. It is difficult to measure the several levels of intracranial pressure during abdominal surgery, and direct monitoring with intracranial devices is often impossible. Measurement of optic nerve sheath diameter (ONSD) via ultrasonography has been developed as an alternative method for evaluating intracranial pressure. The optic nerve is an extension of the central nervous system, surrounded by cerebrospinal fluid (CSF) and continues with the nerve sheath. Increased intracranial pressure may cause in expanding of the optic nerve sheath and may increase the diameter. Therefore, measuring the diameter of the optic nerve sheath via ultrasonography is considered as a non-invasive, easy-to-apply and reliable method to evaluate intracranial pressure. In this study, we aimed to evaluate the changes of optic nerve sheath diameter in patients who will undergo laparoscopic colon and gynecologic surgery during trendelenburg position. Our primary goal is to compare the optic nerve sheath diameters via ultrasonography, and our secondary aim is to evaluate the effect of this change on intracranial pressure.

Conditions

Interventions

TypeNameDescription
OTHEROptic nerve sheath diameterPre and post-trendelenburg optic nerve sheath diameter will be measured

Timeline

Start date
2020-07-15
Primary completion
2021-04-30
Completion
2021-04-30
First posted
2020-06-11
Last updated
2021-05-20

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT04428229. Inclusion in this directory is not an endorsement.