Clinical Trials Directory

Trials / Unknown

UnknownNCT04416009

Extracellular Water in Covid 19 Pneumonia

the Determination of Extracellular Water (ECW) Which is Detected by Bioimpedence Method on Severe and Mild Covid 19 Pneumonia Clinical Course

Status
Unknown
Phase
Study type
Observational
Enrollment
52 (estimated)
Sponsor
Gaziosmanpasa Research and Education Hospital · Other Government
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

According to various studies Covid 19 pneumonia has a very similar clinical course to Acute Respiratory Distress Syndrome (ARDS) which has clarified by Berlin definition. Based on this similarity, extracellular fluid of lungs and diffuse alveolar damage should be observed in covid 19 pneumonia as well. Extracellular water (ECW) can be determine by using whole body bioimpedence system (NİCaS). The aim of this study is to investigate the effect of ECW on the clinical apperence of covid 19 pneumonia clinical course.

Detailed description

Increase in the extracellular water of lungs is the major pathophisilogy of ARDS. According to various studies Covid 19 pneumonia has a very similar clinical course to Acute Respiratory Distress Syndrome (ARDS) which has clarified by Berlin definition. Depending on the similarity of Covid 19 and ARDS; evaluation of ECW ,can be a determinant of clinical apperence of covid19 pneumonia. The aim of this study to find the corelation between ECW and severty of the pneumonia. In this prospective -controlled research, the patients who were diagnosed with Covid-19 pneumonia will be evaluated. The ones in the intensive care will be considered as severe, and the ones in the ward will be considered as mild clinical course pneumonia. İn both groups, in addition to other heamodynamic parametres, ECW will be recorded using non-invasive body biooimpedence method by NİCaS machine. The total amount of patients will be 52, 26 each two groups. The ward and intensive care patients will be connected to the NİCaS machine to determine ECW and statistically significantchanges will be recorded. The device consists of a laptop, a software which calculates cardiac parameters and two electrodes. The measurement is done by the following process: one of these electrodes, which looks like ECG electrodes, is stuck to the wrist and the other one to the opposite ankle or each one to two wrists. the severety of illness will try to be detected.Gpower 3 for Mac Os (Faul, F., Erdfelder, E., Buchner, A., \& Lang, A.-G. (2009). Statistical power analyses using G\*Power 3.1: Tests for correlation and regression analyses. Behavior Research Methods, 41, 11491160.) was used for istatistical power analysis.The power analysis was done priorly and based on the T-test.In order to provide enoughsample magnitude power, which is 0.8, it was calculated that each group should have 26 patients which makes at total of 52 Statistical method: The normal distribution of data will be evaluated using Kolmogorov-Smirnov test. Parametric ones will be used in normal distrubitions, non-parametric ones will be used in abnormal distrubitions. İntergroup ECW values will be compared via independent sample T test. In catagoric data, the comparisons will be made with Pearson Ki square test, and the p values less then 0.05 will be considered as significant.

Conditions

Interventions

TypeNameDescription
DEVICENİCaSwhole body bioimpedence method

Timeline

Start date
2020-07-05
Primary completion
2020-12-20
Completion
2021-02-20
First posted
2020-06-04
Last updated
2020-06-04

Locations

1 site across 1 country: Turkey (Türkiye)

Regulatory