Summary

Bell's palsy (idiopathic facial palsy) is the most common peripheral lesion of the cranial nerves and the most common mono-neuropathy. Therapeutic ultrasound (US) is among the commonly used physical modalities for treating musculoskeletal disorders. The effects of US are due to alteration of cell membrane activity, vascular wall permeability and facilitation of tissue healing. The aim of this study is to investigate the effect of pulsed US treatment in patients with Bell's palsy when added to superficial heating, massage and exercise therapies.

Detailed description

In this double -blind, randomized placebo-controlled trial, 32 patients (aged 18-65 years) diagnosed as idiopathic facial palsy with appropriate criteria were included. All patients were evaluated with motor nerve conduction studies and electromyography at 3-4 weeks after the onset of paralysis and 3 months after the treatment. Paralytic side frontalis and orbicularis oris muscles were used for electrophysiological analysis. Electrophysiological examinations were performed by an experienced electromyographer who was blind to the patient's treatments. Patients were separated into two groups as Group 1 (pulsed ultrasound therapy) and Group 2 (sham). Both groups were undergone to a conservative treatment program (20 min hot pack, massage 20 min and facial expression exercises) for 3 weeks, 5 days a week. In group 1 pulsed US treatment (frequency: 1000 kHz, intensity: 0.5w/cm2, on-off ratio: 1:2, duration 5 min) were applied to the paralyzed facial muscles. The patients in group 2 received exactly the same procedure as the treatment group, except that the power switch was off. All treatments were applied for 5 days a week for 3 weeks by the same 5-cm2 head US device (Enraf-Nonius Sonopuls 434) and the same physiotherapist. Patients were assessed at baseline, after last session, and 3 months after the treatment. Sunnybrook Facial Grading System, House Brackmann Facial Grading System and Facial Disability Index and electrophysiologic parameters were used for outcome evaluation.

Conditions

Interventions

TypeNameDescription
DEVICETherapeutic Pulsed UltrasoundPatients in pulsed ultrasound group received pulsed ultrasound treatment (frequency: 1000 kHz, intensity: 0.5w/cm2, on-off ratio: 1:2). Pulsed ultrasound treatment were applied with 5-cm2 head Enraf-Nonius Sonopuls 434 ultrasound device.
DEVICESham UltrasoundControl group received sham ultrasound treatment

Timeline

Start date
2019-06-01
Primary completion
2020-03-20
Completion
2020-03-20
First posted
2020-06-02
Last updated
2020-06-02

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT04412733. Inclusion in this directory is not an endorsement.