Clinical Trials Directory

Trials / Suspended

SuspendedNCT04364308

The Relationship Between Umbilical Cord ph and Feto-maternal Doppler Studies in Scheduled Nonlaboring Term Singleton Caesarean Deliveries

Status
Suspended
Phase
Study type
Observational
Enrollment
100 (estimated)
Sponsor
University of Campania Luigi Vanvitelli · Academic / Other
Sex
Female
Age
18 Years – 44 Years
Healthy volunteers
Accepted

Summary

Perinatal asphyxia is a crucial reason for neonatal and childhood morbidity and death. Fetal and neonatal acidemia can be utilised as predictors for establishing such risk. Several researches have reported a marked relation between low values of fetal pH with short- and long-term adverse neonatal outcomes. Umbilical cord blood gas studies (UCGS) are considered critical data that gives an objective and certified evaluation of the oxygenation and metabolic status of the fetus. Before birth, the physician can evaluate fetal wellness through cardiotocography and prenatal ultrasound. Other studies had examined the role of fetal Doppler indices before birth and proposed that fetuses with lower impedance in the middle cerebral artery (MCA) or low cerebroplacental ratio (CPR) are at increased risk of adverse pregnancy outcome. However, no research has ever evaluated the possibility of a correlation between ultrasonographic fetal evaluation and fetal umbilical cord pH as a predictor of pre-delivery fetal pH. The goal of our study was to discovered a potential association between the venous umbilical ph cord blood at delivery and the ultrasonographic feto-maternal doppler indices in patients with a scheduled nonlaboring term singleton caesarean deliveries (SCD), this research is a novel finding.

Detailed description

the investigators included in our study only singleton term (37 0/7 - 41 6/7 weeks of gestation) pregnancies delivered by a scheduled nonlaboring term singleton caesarean deliveries. This was an observational study carried out at a single university tertiary care center For every patient, an ultrasound examination was performed within one day of delivery and the fetal doppler indices were recorded. The umbilical venous pH were obtained immediately after delivery and before placental detachment with heparinized syringes The primary endpoints were CPR, umbilical (UA) and fetal MCA arteries indices. The second endpoints analysed when measurable were ductus venosus (DV) and uterine artery (Ut) pulsatility indices, all indices were examined using colour Doppler ultrasound according to a standard procedure and CPR was evaluated as the ratio between the MCA and UA pulsatility indices. The venous umbilical cord pH at birth was correlated with ultrasound doppler parameters, calculating the correlation coefficient r2 and P-value. Statistical significance was fixed at P\<0.05. the investigators performed a linear regression analysis to find the association between the different ultrasound indices and the venous pH.

Conditions

Interventions

TypeNameDescription
OTHERFetal EchographyFetal ultrasound and its parameters

Timeline

Start date
2019-04-01
Primary completion
2020-04-19
Completion
2024-09-01
First posted
2020-04-28
Last updated
2023-11-29

Locations

1 site across 1 country: Italy

Source: ClinicalTrials.gov record NCT04364308. Inclusion in this directory is not an endorsement.