Clinical Trials Directory

Trials / Completed

CompletedNCT04357301

Tight Closed-loop Systolic Arterial Pressure Control

Tight Systolic Arterial Pressure Control Using a Closed-loop System for Vasopressor Infusion in Patients Undergoing High-risk Abdominal Surgery: A Proof-of-Concept Study

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
12 (actual)
Sponsor
Erasme University Hospital · Academic / Other
Sex
All
Age
18 Years – 99 Years
Healthy volunteers
Not accepted

Summary

The purpose of this case series is to evaluate the performance of a novel closed-loop (automated) vasopressor administration system that delivers norepinephrine using feedback from standard operating room hemodynamic monitoring (EV1000 monitoring device, Edwards Lifesciences, Irvine, USA).

Detailed description

In this case series, the investigators will report the percentage of case time in hypotension (defined as systolic arterial pressure (SAP) \< 117mmHg). The target mean arterial pressure (MAP) will be set at a SAP of 130mmHg in all patients. Definition of Hypotension is target SAP - 10% (130mmHg - 13 mmHg = 117 mmHg). We will use the same SAP target in all patients even if we used a modified definition of hypotension from the study of Futier and colleagues ( JAMA 2017). We won't use a individualized SAP for each patient but the same SAP target in all patients. The investigators want to demonstrate that the closed-loop system can prevent hypotension at this specific set point. The Investigators have shown the system works well based on a target MAP but not yet using a target of SAP. The investigators will test the system in a pilot study of 13 patients undergoing High-risk abdominal surgery which require the placement of a arterial catheter, the optimization of fluid therapy and a tight SAP control. Participants will receive standard patient care in that in no way will their anesthetic or surgical procedure will be altered as part of the study, with the exception of vasopressor administration ( automatically delivery instead of manually adjustments) Fluids will be given as goal directed fluid therapy in order to maintain stroke volume variation below 13% (hospital guidelines).

Conditions

Interventions

TypeNameDescription
DEVICEClosed-loop vasopressorThe system will adjust the norepineprhine infusion rate based on a target SAP of 130 mmHg in 20 patients

Timeline

Start date
2020-09-25
Primary completion
2020-10-30
Completion
2020-10-30
First posted
2020-04-22
Last updated
2021-03-15

Locations

1 site across 1 country: Belgium

Source: ClinicalTrials.gov record NCT04357301. Inclusion in this directory is not an endorsement.