Clinical Trials Directory

Trials / Completed

CompletedNCT04349085

Effects of Photobiomodulation Therapy Combined With Static Magnetic Field in CrossFit® Athletes

Effects of Photobiomodulation Therapy Combined With Static Magnetic Field Applied in Different Moments on Performance and Muscle Recovery in CrossFit® Athletes

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
12 (actual)
Sponsor
University of Nove de Julho · Academic / Other
Sex
Male
Age
18 Years – 35 Years
Healthy volunteers
Accepted

Summary

Crossfit® is a method of strength training and fitness built on functional movements, constantly varied and executed at high intensity. Competitions such as the Crossfit® involve physically demanding activities, which in addition to being performed at high intensity also use great measures of aerobic capacity related with performance. These characteristics cause metabolic and muscular stress, as well as a decrease in physical performance. The demand for intensity is the cause of concern regarding the practice of Crossfit® and the risk of injuries. Studies using photobiomodulation therapy combined with static magnetic fields (PBMT/sMF) to delay fatigue and increase performance have obtained positive results in different types of exercise and application times. However, there are no studies investigating the effects of PBMT/sMF in training with similar characteristics as Crossfit®. Therefore, the aim of this project is to verify the effects of PBMT/sMF on performance and muscle recovery of Crossfit® athletes at different times of application (pre workout of the day \[WOD\] and/or post WOD) in order to determine the best way to use the therapy.

Detailed description

To achieve the proposed objective it will be performed a randomized, crossover, triple-blind (volunteers, outcome assessors and therapists), placebo-controlled trial. Twelve volunteers will be allocated to four interventions/situation. The order of the interventions/situations will be randomized. The volunteers will be treated by a blinded therapist. The outcomes will be obtained at baseline (prior to WOD), and 1 hour, 24 and 48 hours after WOD. Except for the ratings of perceived exertion that will be obtained at baseline, after WOD, and 1 hour, 24 and 48 hours after WOD. In addition, for the functional analysis the data will be collected at baseline, after applied intervention, and 1 hour, 24 and 48 hours after WOD. The data will be collected by a blinded assessor. The WOD will be consisted in finish as quickly as possible a sequence of three exercises (Calories in Assault AirBike®, Hang Squat Clean and Box Jump Over), in a well-known series model for the athletes, without rest. The investigators will analyze: ratings of perceived exertion; activity of creatine kinase (CK); levels of the cytokine Interleukin-6 (IL-6), and maximum number of free squat reps in 1 minute. Statistical analysis: All data will be analyzed both in their absolute values and in relation to their percentage variation from the values obtained in the pre-WOD (baseline) assessments. The results obtained will be tested for normality using the Kolmogorov-Smirnov test. If data show normal distribution, the ANOVA test (one or two way depending on the outcome analyzed) with post-hoc Bonferroni will be used. The level of statistical significance will be p\<0.05.

Conditions

Interventions

TypeNameDescription
DEVICEEffective PBMT/sMFA cluster with 20 diodes, manufactured by Multi Radiance Medical® (Solon, OH, USA), will be used: 4 diodes of 905 nm (1.25 average power, 50 W of peak power for each diode), 8 diodes of 850 nm (40 mW of average power for each diode) and 4 diodes of 633 nm (25 mW average power for each diode). Effective PBMT/sMF will be applied in direct contact with the skin and light pressure in: 4 sites in the knee extensor/hip flexor muscles, 3 sites in the knee flexor/hip extensor muscles and 1 site in the plantar flexor muscles. The effective PBMT/sMF will be applied to both lower limbs. The dose used for applications will be approximately 270 J for knee extensors/hip flexors, 180 J for knee flexors/hip extensors, and 60 J for plantar flexors.
DEVICEPlacebo PBMT/sMFA cluster manufactured by Multi Radiance Medical® (Solon, OH, USA) with 20 diodes will be used: Placebo PBMT/sMF will be applied in direct contact with the skin and light pressure in: 4 sites in the knee extensor/hip flexor muscles, 3 sites in the knee flexor/hip extensor muscles and 1 site in the plantar flexor muscles. The placebo PBMT/sMF will be applied to both lower limbs. The dose used for applications will be approximately 0 J per diode. The sounds and signals emitted from the device as well as the information displayed on the screen will be identical, regardless of the type of treatment (active or placebo).

Timeline

Start date
2020-04-17
Primary completion
2020-05-10
Completion
2020-05-10
First posted
2020-04-16
Last updated
2020-07-13

Locations

1 site across 1 country: Brazil

Regulatory

Source: ClinicalTrials.gov record NCT04349085. Inclusion in this directory is not an endorsement.