Clinical Trials Directory

Trials / Unknown

UnknownNCT04342455

A Low-dose Radiation and Contrast Agent Exposure Protocol for Coronary CTA in Diabetic Patients

Evaluation the Diagnostic Efficacy of a Low-dose Radiation and Contrast Agent Exposure Protocol for Coronary Computed Tomography Angiography(CTA)on Coronary Artery Disease in Diabetic Patients

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
400 (estimated)
Sponsor
First Affiliated Hospital Xi'an Jiaotong University · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

To assess diagnostic accuracy,image quality and renal safety of a double low-dose coronary CTA protocol at coronary artery evaluation in patients with diabetes by using invasive coronary angiography(ICA) as the reference method and to compare the results with those obtained traditional dose protocol. The study will randomly include about 400 consecutive participants aged 18 to 80 years old who had been diagnosed with diabetes and suspected coronary artery disease.All participants undergo ICA and coronary CT angiography performed with a whole-heart CT scan.Coronary segment interpretability,image quality based on a four-point Likert scale,blood indicators of renal function will be accessed between double low-dose CTA protocol and traditional CTA protocol. Investigators hypothesize that an individualized coronary CTA protocol that appropriately reduces radiation dose and contrast dose does not affect image quality and diagnostic accuracy, and can reduce the risk of kidney damage in high-risk patients.

Detailed description

The study has been approved by the local ethics committee and allparticipants will be provided written informed consent. Iodixanol 320 mg/ml is injected followed by 30 ml of saline solution.In the test group,the tube voltage,contrast agent volume and flow rate are adapted to cardiac ejection fraction(EF) and body mass index(BMI)according to the pretest. participants in the contract group are injected 50 ml contrast agent with the flow rate of 5 ml/s in tube voltage of 120 kVp. All participants are scanned in automatic tube current.

Conditions

Interventions

TypeNameDescription
OTHERdouble-low scanninga CT angiography protocol with low radiation and contrast agent exposure

Timeline

Start date
2018-10-07
Primary completion
2020-09-15
Completion
2020-12-31
First posted
2020-04-13
Last updated
2020-04-13

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT04342455. Inclusion in this directory is not an endorsement.