Nasal HFOV Versus Nasal SIPPV in Neonate Following Extubation: RCT Crossover Study

Nasal High Frequency Oscillatory Versus Synchronized Intermittent Positive Pressure Ventilation in Neonate Following Extubation: Randomized Controlled Crossover Study

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
133 (actual)
Sponsor
Prince of Songkla University · Academic / Other
Sex
All
Age
1 Day – 1 Month
Healthy volunteers
Not accepted

Summary

Mechanical ventilation was introduced to treat respiratory failure in preterm infants or sick neonates then improvements in survival (1,2). However, the complications from short or long term use of ventilation can result in unintended harm or burden (e.g., air leak syndrome, pneumonia, bronchopulmonary dysplasia, neurological injury, retinopathy of prematurity) (3,4). To reduce these risks, clinicians should aggressive extubated neonates as early as possible. Respiratory (focus on blood gas as well as partial pressure CO2 \[pCO2\]) or extubation (focus on clinical condition as well as reintubation) failure was worrisome in pediatrician and parents if the neonate was reintubated owing to complete recovery of lung disease or inadequate respiratory drive. Non-invasive ventilation (NIV) was supported for primary respiratory support (initial mode before endotracheal intubation) or post-extubation. Nasal continuous positive airway pressure (nCPAP) was familiar to NIV mode in neonatal respiratory support. Nowadays, the new NIV modalities are nasal intermittent synchronized positive pressure ventilation (nSIPPV) and nasal high frequency oscillation (nHFO). To increase the likelihood of nCPAP success, other new modalities of NIV may be interesting. From theory, nSIPPV and nHFO combines peak inspiratory pressure (PIP) with synchrony and high-frequency oscillations without synchrony above CPAP, respectively. From meta-analysis, nSIPPV and nHFO were statistically significant superior than nCPAP both respiratory and extubation failure in neonate (5,6). The aim of our study was to investigate the efficacy of nHFOV and nSIPPV for CO2 clearance and reintubation rate after extubated neonates. The investigators hypothesized that nHFOV mode would improve CO2 clearance better than nSIPPV mode.

Detailed description

The primary outcome (pCO2) was measured by crossover RCT. The secondary outcome (reintubation within 7 days) was measured by paralleled RCT.

Conditions

Interventions

TypeNameDescription
DEVICENon-invasive ventilationIntervention nasal high frequency oscillatory ventilation (nHFOV) and nasal synchronized intermittent positive pressure ventilation (nSIPPV) were generated by neonatal ventilators (SLE6000 infant ventilators, United Kingdom) using bi-nasal prongs (RAM cannula, NEOTECH®, USA) or the nasal mask of the same type for both ventilation modes. The size of the prongs was determined by the infant's weight. The largest possible prongs were used, with a snug fit to avoid leakage. Pacifier for preterm and term neonate (Jollypop™, USA) was taken to avoid leakage from the mouth. The disposable ventilator circuit (Fisher \& Paykel RT268™, Evaqua Dual Limb Infant Breathing Circuit Kit with Evaqua 2 Technology and Pressure Line, Flow \> 4L/min, New Zealand) was used. The initial NIV setting was (7) described in arm description. (above)

Timeline

Start date
2020-07-01
Primary completion
2022-06-30
Completion
2022-08-01
First posted
2020-03-26
Last updated
2025-03-03
Results posted
2025-03-03

Locations

1 site across 1 country: Thailand