Trials / Terminated
TerminatedNCT04279925
A Clinical Trial of Locally Made Titanium Miniplate and Screw in Maxillofacial Fractures Management
- Status
- Terminated
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 9 (actual)
- Sponsor
- Indonesia University · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Accepted
Summary
The study is a blind randomized clinical study on patients with midface maxillofacial fractures coming to Cipto Mangunkusumo Hospital. The subject is the fracture line who met the inclusion criteria and randomly allocated into the study (locally-made miniplate and screw) and control (BIOMET® miniplate and screw) group through a predetermined randomization list. The healing process is follow up using non-contrast head computed tomography immediately after surgery as a baseline, and 3 months post-op. Afterward, a radiologist consultant as a blinded evaluator will evaluate the score of bone density, and screw loosening, while local tissue reaction after fixation evaluates during the patient's visit outpatient clinic. All scores from points of the evaluation group will be collected and going to statistically evaluated using independent t-test or Mann Whitney test depending on the distribution of the data
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | ORIF (Open reduction internal fixation): locally-made miniplate and screw | Fracture lines in this group underwent open reduction internal fixation (ORIF) procedure which consists of realignment of the bone achieved from surgical mean and stabilization of the bone fragments by using locally-made miniplate and screw produced by the Faculty of Engineering Universitas Indonesia. The plate used in the study is a straight plate with 4 and 5 holes with the dimension of 17mm long, 4 mm wide and 0.56 mm thick. |
| DEVICE | ORIF: Imported miniplate and screw | Fracture lines in this group underwent open reduction internal fixation (ORIF) procedure which consists of realignment of the bone achieved from surgical mean and stabilization of the bone fragments by using Biomet® miniplate 1.5 produced by Biomet, included in the Lorenz® Plating System Midface. The particular plate used in the study is a straight plate with 4 holes, 17mm length and 0.6mm thick, coded 01-7047 in the catalog. Biomet® screw 1.5 utilized in this study is also produced by Biomet, included in the Lorenz® Plating System Midface. The dimension of the screw is 4mm length, 1.5 mm diameter, and coded 91-6104 1.5 mm X-Drive Self drilling screws. |
Timeline
- Start date
- 2020-03-11
- Primary completion
- 2020-05-31
- Completion
- 2020-05-31
- First posted
- 2020-02-21
- Last updated
- 2022-04-26
- Results posted
- 2022-04-26
Locations
1 site across 1 country: Indonesia
Source: ClinicalTrials.gov record NCT04279925. Inclusion in this directory is not an endorsement.