Clinical Trials Directory

Trials / Unknown

UnknownNCT04266327

RISI in the Treatment of Recurrent Metastatic SCC of Thoracic Inlet Lymph Nodes

Study on the Safety and Efficacy of 3D-printed Template Assisted Ct-guided RISI in the Treatment of Recurrent Metastatic Squamous Cell Carcinoma of Thoracic Inlet Lymph Nodes After Radiotherapy: a Multi-center Prospective Cohort Study

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
30 (estimated)
Sponsor
Peking University Third Hospital · Academic / Other
Sex
All
Age
18 Years – 75 Years
Healthy volunteers
Not accepted

Summary

The malignant tumor at the thoracic entrance is difficult to be surgically removed, and radiotherapy or radiotherapy based comprehensive treatment is often chosen at the initial diagnosis. However, for patients with recurrence after radiotherapy, there is basically no ideal local treatment.The Radioactive i-125 Seed Implantation (RISI) therapy is characterized by high dose within the tumor target area and low dose to surrounding normal tissues, and its radiation dose rate is low, which theoretically benefits the protection of normal tissues and is more suitable for the salvage treatment of recurrent lesions after radiotherapy.3 d printing template technology is through the advance of the preoperative plan design and optimization, to achieve better avoid endanger organs, template of individualized and human body surface after laminating, registration accuracy, its guide pillar to precise control the direction of the needle, the present data show that in the template with CT guided by solid tumors as well had significantly higher accuracy, as the actual target dose of basic postoperative can reach the design request of the preoperative planning, so the application of 3 d printing template helps to further improve the operation efficiency and safety, also has potential promotion effect to curative effect. The purpose of this study is: (1) Observe the efficacy, toxicity and side effects of 3d-printed template assisted ct-guided RISI in the treatment of recurrent metastatic squamous cell carcinoma of thoracic inlet lymph node after radiotherapy, and evaluate its safety and effectiveness; (2) to explore the relationship between the efficacy, toxicity and side effects of relapsed metastatic squamous cell carcinoma of thoracic inlet lymph node after radiotherapy with different RISI doses;(3)the related influencing factors affecting the effect/toxicity of RISI in the treatment of relapsed lymph node metastatic squamous cell carcinoma at the thoracic inlet after radiotherapy were analyzed.

Detailed description

This is a non-randomized, prospective, single-arm, cohort study.Patients meeting the inclusion criteria were enrolled successively in the order of admission and treatment.In this study, the dose interval was set as 110-130gy, and a total of 30 patients were expected to be enrolled. The prescription dose was planned to be grouped into 15 patients of 110-120gy and 120-130gy respectively. The specific situation was subject to the actual postoperative verification dose.

Conditions

Interventions

TypeNameDescription
RADIATION3D-printing Template-assisted CT-guided I-125 Seed Implantation(1) positioning and preoperative plan design;(2) 3D printing template design and production;(3) reset and seed implantation;(4) intraoperative optimization;Postoperative dose verification.Dosimetric parameters include: dose D90 and D100 reaching a certain percentage target volume;Target volume V100, V150 and V200 reaching a certain percentage of prescribed dose;And the dose of organs at risk: Dmean, D2cc, d0.5cc, d0.1cc.Regular follow-up was conducted after treatment.

Timeline

Start date
2020-05-01
Primary completion
2024-04-30
Completion
2025-04-30
First posted
2020-02-12
Last updated
2023-12-27

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT04266327. Inclusion in this directory is not an endorsement.