Trials / Unknown
UnknownNCT04249102
Prospective Randomized Clinical Trial Assessing the Short Term Clinical Impact of Continuous vs Flash Glucose Monitoring in Children, Adolescents and Young Adults With Type 1 Diabetes
Prospective Randomized Clinical Study Assessing the Clinical Impact of Continuous vs Flash Glucose Monitoring During a 8 Weeks Period in Children, Adolescents and Young Adults 4 to 20 Years Old With Type 1 Diabetes Previously Using Flash Glucose Monitoring
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 80 (estimated)
- Sponsor
- Queen Fabiola Children's University Hospital · Academic / Other
- Sex
- All
- Age
- 4 Years – 20 Years
- Healthy volunteers
- Not accepted
Summary
Impaired hypoglycemia awareness, a significant problem for children with type 1 diabetes, is defined as neurogenic symptom response before autonomic response to hypoglycemia. Avoiding hypoglycemia appears to restore hypoglycemia awareness. Investigators have previously demonstrated in a retrospective study that Flash Glucose Monitoring system decreased the risk of severe hypoglycemia in type 1 diabetic children and adolescents, even though Flash Glucose Monitoring system, unlike Continuous Glucose Monitoring system, does not provide glucose alerts. Continuous Glucose Monitoring system, by providing real-time data with alarms, could benefit to subjects still experiencing severe hypoglycemia with Flash Glucose Monitoring system. Besides, in adults, Continuous Glucose Monitoring system reduced more effectively impaired hypoglycemia awareness compared to Flash Glucose Monitoring system. In that context, investigators would like to assess the impact of Continuous Glucose Monitoring system instead of Flash Glucose Monitoring system on hypoglycemia in children and adolescents with type 1 diabetes.
Detailed description
All subjects will start with a 7 days run-in phase using their current Flash Glucose Monitoring System associated with a blind Continuous Glucose Monitoring system (Envision, Medtronic). After one week, subjects randomized in the the interventional group will be provided with the Continuous Glucose Monitoring (Guardian Connect, Medtronic) and trained by dedicated diabetes educators for Continuous Glucose Monitoring usage including insertion of the sensor, calibration of the device twice daily and interpretation of the data. Subjects will use the sensors according to the license. For both groups, insulin doses decisions are made by the participant according the received education. After one week, all subjects will be contacted by phone focusing on the use of the technology. The treatment period is 8 weeks. The last week of the treatment period, subjects will use the blind Continuous Glucose Monitoring system (Envision, Medtronic) in addition to their allocated Glucose Monitoring system.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Guardian Connect, Medtronic | Guardian Connect is real-time continuous glucose sensor systems which provide glucose information updated every 5 minutes |
| DEVICE | Abbott Diabetes Care | Abbott Diabetes Care is a Flash Glucose Monitoring system that provides up to 8 hours of retrospective continuous glucose monitoring data to users when the monitor is waved in proximity with the sensor. |
Timeline
- Start date
- 2020-03-12
- Primary completion
- 2022-02-01
- Completion
- 2022-02-01
- First posted
- 2020-01-30
- Last updated
- 2020-03-31
Locations
1 site across 1 country: Belgium
Source: ClinicalTrials.gov record NCT04249102. Inclusion in this directory is not an endorsement.