Clinical Trials Directory

Trials / Completed

CompletedNCT04228874

Effect of Stent Size on Dyssynchrony

The Short Term Effect of Stent Size and Number on Left Ventricular Mechanical Dyssynchrony After Elective PCI to Left Anterior Descending Artery

Status
Completed
Phase
Study type
Observational
Enrollment
265 (actual)
Sponsor
Benha University · Academic / Other
Sex
All
Age
18 Years – 75 Years
Healthy volunteers
Not accepted

Summary

the effect of stent size and number on left ventricular mechanical dyssynchrony after PCI using drug eluting stent is not clear enough

Detailed description

Background: the effect of stent size and number on left ventricular mechanical dyssynchrony after PCI using drug eluting stent is not clear enough Aim: to study short term effect of stent size and number on left ventricular mechanical dyssynchrony after elective PCI to LAD artery. Patients and methods: the study included 150 adult patients with electively stented LAD lesion with DES. Patients were evaluated pre PCI then follow up at 1m and 3m using tissue synchronization image (TSI).

Conditions

Interventions

TypeNameDescription
DEVICEcoronary artery stentsCoronary angiography was done for all the patients according to the Judkins technique. All images were evaluated by an experienced operator, significant coronary artery disease was defined as \> 70 % luminar diameter stenos. The following data was obtained: * Site of stent implantation within LAD. The first Diagonal branch serves as the boundary between the proximal and mid portion of the LAD. Thus, the portion of the artery prior to the origin of the 1st diagonal is known as the proximal LAD, while the segment just below the1st diagonal branch is the mid LAD. The distal segment of the LAD is the terminal third of the artery (Cao et al., 2017). * Length, diameter and number of stents. * TIMI flow after stent deployment.

Timeline

Start date
2018-01-01
Primary completion
2019-12-01
Completion
2019-12-01
First posted
2020-01-14
Last updated
2020-01-14

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT04228874. Inclusion in this directory is not an endorsement.