Clinical Trials Directory

Trials / Unknown

UnknownNCT04217434

Comparative Evaluation of Various Patient Centered Outcomes Following Gingival Depigmentation Using Diode LASER in Different Modes: A Randomized Clinical Trial

A Comparative Evaluation of Various Patient Centered Outcomes Following Gingival Depigmentation Using Diode LASER in Different Modes: A Randomized Clinical Trial

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
40 (estimated)
Sponsor
Krishnadevaraya College of Dental Sciences & Hospital · Academic / Other
Sex
All
Age
18 Years – 45 Years
Healthy volunteers
Accepted

Summary

Purpose of this study is to clinically evaluate and compare various patient centered outcomes using diode LASER in Continuous mode (CW) and Pulsed Mode (PM) using 300µm and 400µm fiber for depigmentation procedure.

Detailed description

The colour of gingiva has a tremendous impact on the esthetics of the smile. Clinically gingival melanin hyperpigmentation is presented as 'black gum' which is common esthetic problem especially for those who have gummy smile. Currently the growing aesthetic concerns among the patients require the removal of hyper pigmented gingival areas to create an aesthetically-pleasant smile. The harmony of the smile is determined not only by the shape, position and colour of the teeth or lips as well as by the by the gingival tissues.Several attempts have been made for removal of gingival pigmentation by different techniques like scalpel, electrocautery, LASER etc. Each technique has its own advantages and disadvantages. In the present study an effort has been made to compare two different modes viz. Continuous mode and Pulsed mode of LASER in the treatment of depigmentation.Diode LASERs for dentistry operate in the near infrared region. The most commonly used wavelengths are 810, 940 and 980 nm , because these wavelengths are very well absorbed by pigmented tissues, haemoglobin and melanin.There are several different ways LASER light operates: Continuous wave (CW), Pulse wave mode (PM). The continuous wave diodes emit continuous LASER energy with a fixed power output for the entire duration. Pulse modulated diodes create a 'pulse' by cutting the beam or turning LASER on \& off \[1s\] at regular intervals. During the first years of diode LASER treatment in dentistry only CW mode was possible but application of 3-4 Watt in CW mode led to carbonization of the soft tissue.To approach better results in soft tissue treatment without much carbonization it was necessary to interrupt the CW mode. That was done by chopping the CW mode. Pulses down to several 100μs were released.LASER in Continuous wave mode is suggested in some studies to cause increase in surgical site temperature which may cause necrosis or jeopardize healing. Application of the LASER in Pulsed mode prevents overheating of surrounding tissues. This study aims to determine the comparative increase in the onsite temperature between the two modes.Decrease in post-operative pain is likely to reduce the consumption of Non-steroidal Anti-inflammatory Drugs (NSAID's). The study aims to quantify the need for NSAID's post-operatively in both Pulsed and continuous wave modes and also in 300µ and 400µ fibers. The change in the diameter of the fibers used in LASER irradiation could bring about a change in the outcome of the procedure as small diameter fibers means high energy density, faster cutting and more heat whereas with larger diameter fibers more energy is needed to cover a broader area to work more quickly and less heat.

Conditions

Interventions

TypeNameDescription
PROCEDURE400 µm fibre length will be used in continuous contact modeDiode LASER (A.R.C Fox, Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®\[ 2% lignocaine in 1:80000 adrenaline\]. LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes using 400 µm fibre length will be used in continuous contact mode at a power setting of 1.5 - 3W. Simultaneously, increase in temperature on site will be recorded using FLUKE 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain.Post operative instructions will be given.
PROCEDURE400 µm fibre length will be used in pulsed contact modeDiode LASER (A.R.C Fox, Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®\[ 2% lignocaine in 1:80000 adrenaline\]. LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes using 400µm fibre length will be used pulsed contact mode at a power setting of 1.5 - 3W. Simultaneously, increase in temperature on site will be recorded using FLUKE 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain.Post operative instructions will be given.
PROCEDURE300 µm fibre length will be used in continuous modeDiode LASER (A.R.C Fox, Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®\[ 2% lignocaine in 1:80000 adrenaline\]. LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes using 300 µm fibre length will be used continous contact mode at a power setting of 1.5 - 3W. Simultaneously, increase in temperature on site will be recorded using FLUKE 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain.Post operative instructions will be given.
PROCEDURE300 µm fibre length will be used in pulsed contact modeDiode LASER (A.R.C Fox, Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®\[ 2% lignocaine in 1:80000 adrenaline\]. LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes using 300 µm fibre length will be used pulsed contact mode at a power setting of 1.5 - 3W. .Simultaneously, increase in temperature on site will be recorded using FLUKE 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain.Post operative instructions will be given.

Timeline

Start date
2018-11-20
Primary completion
2020-03-21
Completion
2020-11-22
First posted
2020-01-03
Last updated
2020-01-03

Locations

1 site across 1 country: India

Source: ClinicalTrials.gov record NCT04217434. Inclusion in this directory is not an endorsement.