Clinical Trials Directory

Trials / Completed

CompletedNCT04185987

Evaluation of the Contamination of Ligatures

Evaluation of the Contamination of Elastomeric Ligatures

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
10 (actual)
Sponsor
University of Gaziantep · Academic / Other
Sex
All
Age
12 Years – 14 Years
Healthy volunteers
Not accepted

Summary

This crossover, in-vivo study was carried out with 10 patients who have been started to be treated at Orthodontics Department. 3 elastomeric ligatures were examined in terms of microbiological and surface roughness.

Detailed description

The development of dental plaque has been associated with several environmental and individual factors including diet composition, oral hygiene, the quality of saliva, the composition of the oral microflora and immune factors. Orthodontic fixed appliances also impede the maintenance of oral hygiene. Plaque accumulation surrounding orthodontic appliances leads to enamel demineralization caused by organic acids produced by bacteria in the dental plaque. In patients with fixed orthodontic treatment, common pathological changes are gingivitis, bleeding and gingival growth; thus, gingival index and plaque index parameters have been used as indicators of periodontal disease in many studies. Enamel demineralization which results in white spot formation is observed due to the increase in the number and volume of acid-producing bacteria, and the decrease in pH level because of the glucose metabolized by these cariogenic bacteria . The most commonly investigated bacteria among those mentioned above is Streptococcus Mutans. In the literature, it has been the subject of many studies, including those investigating the correlation between the S. mutans count and the amount of adhesive left between brackets and the enamel, adhesion of S. mutans to nickel titanium and copper-nickel brackets, the difference in S. mutans colonization between self-ligation system and normal brackets, and the effect of elastomeric rings and ligature wires on S. mutans colonization. Non-conventional elastomeric ligatures were produced in order to reduce the friction of orthodontic sliding mechanics. Manufacturers claim that non-conventional elastomeric ligatures reduced ligation friction by 60% compared to conventional modules. It was reported in another study that brackets combined via non-conventional elastomeric ligatures resulted in a reduced friction force compared to conventional elastomeric ligatures in any wires from 14-inch NITI to 19.25 SS. To our current knowledge, bacterial colonization on non-conventional elastomeric ligatures was investigated in one study only, using microbial culture technique. In light of this information, present study was aimed to compare S. mutans colonization among different commercial types of non-conventional ligatures and ligature wires. The surface structures of these ligature types also will be investigated by atomic force microscope (AFM) and the results of this investigation will be associated with the results of bacterial colonization amount.

Conditions

Interventions

TypeNameDescription
OTHERLeone slide low friction elastomeric ligatureLeone slide low friction elastomeric ligature application
OTHERRMO tough - o energy elastomeric ligatureRMO tough - o energy elastomeric ligature application
OTHERDentsply sili tie elastomeric ligatureDentsply sili tie elastomeric ligature application
OTHERAO twisted ended ligature wireAO twisted ended ligature wire application

Timeline

Start date
2017-08-10
Primary completion
2018-01-20
Completion
2018-03-20
First posted
2019-12-04
Last updated
2020-07-16

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT04185987. Inclusion in this directory is not an endorsement.