Trials / Unknown
UnknownNCT04181216
Comparison of Anatomically Aligned and Conventional Total Knee Arthroplasty in the Same Patients
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 100 (estimated)
- Sponsor
- The Catholic University of Korea · Academic / Other
- Sex
- All
- Age
- 19 Years
- Healthy volunteers
- Not accepted
Summary
Total knee arthroplasty(TKA) is a successful orthopedic surgery with excellent clinical outcome and survival. However, there are concerns about patient satisfaction in previous reports, and dissatisfaction rate of 15-30% is reported in clinical outcomes(PROMs) of some studies. Therefore, for improving the patient's outcome and satisfaction after total knee arthroplasty, it is necessary to change the design of the conventional total knee arthroplsaty implant. The knee is a joint structure with several dynamic functions, and not only the skeletal structure but also the soft tissue balance plays an important role in the function of the knee joint. New implants are being developed to overcome the limitations of conventional TKA implant, including the Journey II Bi-cruciate substituting total knee system (JII-BCS; Smith \& Nephew). JII-BCS implant has normal articular geometry, more anatomical femoral shape, lateral tibial convex geometry, and asymmetrical tibial plateau, anterior and posterior cams, which has been shown in experimental studies to produce nearly normal knee movement by reproducing the actual normal anatomical alignment in vivo. The clinical results of the kinematic effects of this anatomcally aligned change are insufficient, and there is also a lack of comparative studies with conventional total knee arthroplasty implant. The purpose of this study is to compare outcomes between anatomically aligned TKA(JII-BCS) and conventional TKA(Legion total knee system, Smith \& Nephew). This study is a randomized controlled study in patients undergoing total knee arthroplasty per day. Radiologic parameter, patients preference and clinical results was investigated in both knee of same patients who received TKA during minimum 2 year follow up.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Anatomically aligned total knee arthroplasty implant | In same patient, one total knee arthroplasty using anatomically aligned total knee arthroplasty implant Other total knee arthroplasty using conventional total knee arthroplasty implant |
Timeline
- Start date
- 2019-12-01
- Primary completion
- 2020-12-31
- Completion
- 2022-12-31
- First posted
- 2019-11-29
- Last updated
- 2019-11-29
Source: ClinicalTrials.gov record NCT04181216. Inclusion in this directory is not an endorsement.