Trials / Completed
CompletedNCT04174729
System for Quantifying the Functional Strength of the Grip and Pinch Movements
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 30 (actual)
- Sponsor
- University of Mogi das Cruzes · Academic / Other
- Sex
- All
- Age
- 20 Years – 39 Years
- Healthy volunteers
- Accepted
Summary
This study developed a system to quantify the functional strength of young adults without motor impairment during grip and pinch movement. Making it possible to know the accuracy of the value of these strength, the range of motion performed and whether the grip force was maintained throughout the range of motion. In addition to checking the functionality, reliability and reproducibility of the system.
Detailed description
Quantifying grip and grip movement is essential as it allows for a basis in upper limb functionality. However, when there is access, it causes changes in the hands and changes the motor in relation to the force and range of motion, or generates changes in activities of daily living. Thus, a system with 5 devices, where each one the devices were prints in three-dimensional, and instrumented with force sensor for static-dynamic force analysis e potentiometer for analysis range of motion, during the execution of movements cylindrical grip, spherical grip, hook grip, pulp-pulp pinch, and pulp- side pinch in different activities of daily living. Elaborated a data storage interface through MATLAB® software that allows recording the data of each device. For the system functionality tests, 30 volunteers were selected for both sexes, young adults between 20 and 39 years old, students of the Physiotherapy and Graduate courses of the University of Mogi das Cruzes. The tests are divided into two sessions and are repeated after 7 days of the first test
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | handgrip strength | First, the hand measurements of each volunteer were evaluated, followed by the measurement of handgrip strength using the Jamar® dynamometer. And later the tests were performed using the system that contains the 5 devices to quantify the hand strength. |
| DEVICE | Door handle device | To evaluate the cylindrical grip movement, a door handle was used, which evaluated the full force in the range of motion. |
| DEVICE | Tap device | To evaluate the spherical grip movement, a tap was used, which evaluated the full force in the range of motion. |
| DEVICE | Door pull handle | To assess the hook grip movement, a door pull handle was used, which assessed the full force in the range of motion |
| DEVICE | Linear Switch device | To evaluate the pulp-pulp pinch movement, a switch was used, which evaluated the full force in the movement of the movement. |
| DEVICE | Door Key device | To assess the pulp-side pinch movement, a door key was used, which evaluated the full force in the range of motion. |
Timeline
- Start date
- 2019-08-05
- Primary completion
- 2019-09-09
- Completion
- 2019-10-29
- First posted
- 2019-11-22
- Last updated
- 2019-12-03
Locations
1 site across 1 country: Brazil
Source: ClinicalTrials.gov record NCT04174729. Inclusion in this directory is not an endorsement.