Clinical Trials Directory

Trials / Completed

CompletedNCT04169607

Effect of Intraoperative Dynamic Compliance Guided Individualized Positive End-expiratory Pressure on Postoperative Atelectasis After Laparoscopic Bariatric Surgery

Effect of Intraoperative Dynamic Compliance Guided Individualized Positive End-expiratory Pressure on Postoperative Atelectasis After Laparoscopic Bariatric Surgery: a Single-center, Double-blind Randomized Controlled Trial

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
40 (actual)
Sponsor
Xuzhou Medical University · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

This study intends to explore the effect of dynamic compliance guided individualized positive end-expiratory pressure titration strategy on reducing the level of postoperative atelectasis in obese patient who have laparoscopic bariatric surgery.The results of the study are to assess the effects of this intervention on the incidence,duration of postoperative atelectasis and other complications including hypoxemia etc. after laparoscopic bariatric surgery.And reducing the burden of postoperative atelectasis on patients and their families, hospitals and public resources.

Conditions

Interventions

TypeNameDescription
PROCEDUREDynamic compliance guided individualized positive end-expiratory pressure titration strategyBasic ventilation: Volume-controlled ventilation (VCV) mode with positive end-expiratory pressure (PEEP) of 8cm H2O after induction of anesthesia, Recruitment maneuver (RM): Pressure-controlled ventilation (PCV) mode increasing PEEP from 10 to 25cmH2O in step of 5cmH2O per 30s. PEEP-titration maneuver: ventilation parameters reset as basic ventilation with PEEP still 25cmH2O.Decrease PEEP to 5cmH2O in step of 2cmH2O per 10 respiratory cycles to confirm the highest dynamic lung compliance (Cdy). After titration: A new RM will be performed and the final PEEP will be the one related to highest Cdy plus 2cm H2O. Randomized after the second RM. Individualized PEEP arm: maintain individualized PEEP; PEEP8 arm: maintain a fixed PEEP of 8cm H2O. VCV with other ventilation parameters the same as basic ventilation until extubation . After discharged from postoperative anesthesia care unit (60 to 90 minutes after extubation): chest CT .

Timeline

Start date
2019-12-16
Primary completion
2020-09-30
Completion
2021-07-19
First posted
2019-11-20
Last updated
2021-07-26

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT04169607. Inclusion in this directory is not an endorsement.

Effect of Intraoperative Dynamic Compliance Guided Individualized Positive End-expiratory Pressure on Postoperative Atel (NCT04169607) · Clinical Trials Directory