Clinical Trials Directory

Trials / Completed

CompletedNCT04125992

Distal vs. Forearm Radial Artery Access

Distal Radial Artery Access in Comparison to Forearm Radial Artery Access for Cardiac Catheterization, a Randomized Controlled Trial

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
212 (actual)
Sponsor
An-Najah National University · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The Distal Radial Access (DRA) to the coronaries has emerged recently. It's done via the distal radial artery in the radial fossa, which is known as the snuff-box. The rationale of conducting this research is to assess this new access advantages and disadvantages, in comparison with the standard conventional forearm radial access and examine if it's worthy to be a future alternative method for coronary angiography. It aims to randomly compare between the new distal radial access via the snuffbox and the conventional forearm radial access for percutaneous coronary angiography and angioplasty procedures. The objectives of comparing both procedures are to analyze the frequency of complications in terms of occlusion, arterial spasm, hematoma, and to weigh accesses effectiveness in terms of time and attempts to puncture, crossover rate, procedure duration, hemostasis time, and convenience of the patients and operators. Candidates for coronary angiography are being randomized into the interventional group to undergo the angiography through the distal radial artery as the access site, or the control group accessing through the radial artery in the forearm. Procedural and post procedural outcomes and complications are being reported while patients are in hospital. All patients undergo doppler ultrasonography within 24 hours after the procedure.

Conditions

Interventions

TypeNameDescription
PROCEDUREdistal radial artery access in coronary angiography and angioplastyThe patient grasps his thumb towards the palm to bring the radial artery up to the surface. The left hand is set on the right side of the groin toward the operator, who stands on the right side, with the dorsal surface of hand upwards. Afterward, the access site is disinfected, lidocaine HCL is SC injected for local anesthesia. Subsequently, the distal radial artery is palpated to find the point of the strongest pulse. Later, at a 45-degree angle, the artery is punctured with a 21-gauge needle and a 0.018 soft, flexible, metallic wire is then inserted in the needle. Through the sheath, 200 micrograms of Nitroglycerin is given. A 5000 unit of unfractionated heparin is administered through the IV line. A weight-adjusted dose of heparin is further added if PCI is needed. Then, a 0.035 wire is introduced in the sheath with other required instruments such as the intracoronary device and the catheters. After pulling out the sheath, a compression device, Safe Guard, is used for hemostasis.
PROCEDUREForearm radial artery access in coronary angiography and angioplastyThe right hand is set in the anatomical position, with the anterior surface of arm face upwards. Afterward, the access site is disinfected, lidocaine HCL is SC injected for local anesthesia. Subsequently, the forearm radial artery is palpated to find the point of the strongest pulse. Later, at a 45-degree angle, the artery is punctured with a 21-gauge needle and a 0.018 soft, flexible, metallic wire is then inserted in the needle. Through the sheath, 200 micrograms of Nitroglycerin is given. A 5000 unit of unfractionated heparin is administered through the IV line. A weight-adjusted dose of heparin is further added if PCI is needed. Then, a 0.035 wire is introduced in the sheath with other required instruments such as the intracoronary device and the catheters. After pulling out the sheath, a compression device, TR band, is used for hemostasis.

Timeline

Start date
2019-12-01
Primary completion
2020-12-21
Completion
2020-12-21
First posted
2019-10-14
Last updated
2023-06-06

Locations

1 site across 1 country: Palestinian Territories