Comparing the Diagnostic Efficacy of Different Suction Techniques for EUS-FNB of Pancreatic Solid Lesions
Comparing the Diagnostic Efficacy of Different Suction Techniques for Endoscopic Ultrasound-guided Fine-needle Biopsy of Pancreatic Solid Lesions Using 25G Procore Needle: a Prospective Randomized Controlled Multicentric Clinical Study
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 300 (estimated)
- Sponsor
- Changhai Hospital · Academic / Other
- Sex
- All
- Age
- 18 Years – 75 Years
- Healthy volunteers
- Not accepted
Summary
There are many factors that can affect the diagnostic yield of EUS-FNA, including lesion factors, the endoscoist experience, the needle size, the number of needle passes, and the suction technique. since diagnostic efficacy of different suction techniques for EUS-FNB is still uncertain, thus we decided to compare the diagnostic efficacy of three common methods: the 10 ml standard negative pressure, slow pull and wet suction.
Detailed description
the standard suction: after the needle is inserted in the mass, removing the stylet before performing EUS-FNA. Then attach a 10mL syringe to the end of needle. 20 times of for-backward Suction was applied after the lesion was punctured. slow-pull : after the needle is inserted in the mass, slowly pull the stylet out while performing EUS-FNA with 20 times for-backward. wet suction: after removing the stylet, the needle was flushed with 5mL of saline solution to replace the column of air with saline. A 10mL syringe was attached to the end of the needle. 20 times of for-backward Suction was applied after the lesion was punctured.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DIAGNOSTIC_TEST | standard suction | After the needle is inserted in the mass, removing the stylet before performing EUS-FNA. Then attach a 10mL syringe to the end of needle. 20 times of for-backward Suction was applied after the lesion was punctured. |
| DIAGNOSTIC_TEST | slow pull | After the needle is inserted in the mass, slowly pull the stylet out while performing EUS-FNA with 20 times for-backward. |
| DIAGNOSTIC_TEST | wet suction | After removing the stylet, the needle was flushed with 5mL of saline solution to replace the column of air with saline. A 10mL syringe was attached to the end of the needle. 20 times of for-backward Suction was applied after the lesion was punctured. |
Timeline
- Start date
- 2019-06-10
- Primary completion
- 2020-05-30
- Completion
- 2020-11-30
- First posted
- 2019-09-24
- Last updated
- 2019-09-24
Locations
1 site across 1 country: China