Trials / Unknown
UnknownNCT04093817
Arrhythmia in on Pump vs. Off Pump Coronary Artery Bypass Grafting
- Status
- Unknown
- Phase
- —
- Study type
- Observational
- Enrollment
- 50 (estimated)
- Sponsor
- Assiut University · Academic / Other
- Sex
- All
- Age
- 40 Years – 80 Years
- Healthy volunteers
- —
Summary
The aim of this research is to know the incidence of arrhythmias in on vs. off pump CABG and to know their relations to the patient's morbidity and mortality, hospital stay and hospital costs.
Detailed description
On pump vs. off pump CABG has been a topic of debate for many years regarding the benefits and the risks of each technique .Off pump CABG began 30 years ago. Its promotion was based on its potential benefits over some of the limitation of traditional on pump CABG. It avoids the trauma of cardiopulmonary bypass (CPB) and minimizing aortic manipulation and reducing length of hospital stay and morbidity. There is a criticism regarding completence of revascularization in off pump vs. on pump CABG, this is no longer valid in the current era as technology to safely perform multi vessel off pump has improved tremendously over the past decade. One of the debates between these two techniques was the incidence of arrhythmias in and after the operation and its relation to morbidity and mortality at the operation and hospital stay after the operation. As known atrial fibrillation (AF) is still the most common arrhythmia that occur after CABG and although in some studies it has been considered a benign and self-limiting complication, some suggest serious morbidity and mortality from this complication, it is said that it affects more than 40% of patients underwent CABG. Atrial fibrillation (AF) may lead to thromboembolic complications, additional pharmacotherapy, longer hospital stay, increase cost, anxiety and stroke. Most AF post CABG are found in the second to third post-operative day. SO, on this study the investigators focus one the incidence of arrhythmias, especially AF in those two techniques and their relations to patients' morbidity and mortality.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | cardio pulmonary bypass machine | cardio pulmonary bypass machine is a machine that work to compensate for the function of the heart and the lungs in the operation |
Timeline
- Start date
- 2021-04-01
- Primary completion
- 2022-05-01
- Completion
- 2022-07-01
- First posted
- 2019-09-18
- Last updated
- 2019-09-18
Source: ClinicalTrials.gov record NCT04093817. Inclusion in this directory is not an endorsement.