Trials / Completed
CompletedNCT04087135
Comparison of Intubation With Direct Laryngoscopy or Videolaryngoscopy in an Hemoptysis Simulated Situation on Human Cadaver Embalmed With Thiel's Method
Comparison of the Success Rate of Intubation With Direct Laryngoscopy or Videolaryngoscopy in an Hemoptysis Simulated Situation on Human Cadaver Embalmed With Thiel's Method
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 25 (actual)
- Sponsor
- Université de Montréal · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Accepted
Summary
Our study first aims to develope a realistic cadaver model of hemoptysis based on Thiel's embalmed cadavers. Secondly, participants will intubate the hemoptysis cadaver model with (a) the direct laryngoscopy with MacIntosh blade, (b) the videolaryngoscopy with McGrath XBlade and (c) the videolaryngoscopy with McGrath XBlade and a suction advance before the optic of the camera. We hypothesis that, in simulated hemoptysis on the Thiel's embalmed cadaver, the rate of failed intubation at first try will be different depending on the laryngoscope used.
Detailed description
For the simulation of hemoptysis, we will need to use the Thiel's embalmed cadaver, who's realism is established, create a synthetic form of blood resembling real blood by its viscosity and color for the simulation and elaborate the dynamic interface of the simulation of hemoptysis. The quantity and way of administration of the blood through the trachea will be tested to obtain a realistic hemoptysis as seen in supraglottic. For the simulation, we will compare the efficiency of intubation, judged by the failure rate of intubation on first try, for (a) the direct laryngoscopy with MacIntosh blade, (b) the videolaryngoscopy with McGrath XBlade and (c) the videolaryngoscopy with McGrath XBlade with the suction advanced before the camera. We will also measure the time to intubation, the failure rate of intubation, the suction use and the difficulty of intubation as reported by the participants.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | direct laryngoscopy | Participants will intubate the hemoptysis cadaver model in simulation with direct laryngoscopy MacIntosh blade. |
| OTHER | videolaryngoscopy McGrath | Participants will intubate the hemoptysis cadaver model in simulation with videolaryngoscopy using McGrath and the short curved blade (XBlade) |
| OTHER | videolaryngoscopy McGrath with suction | Participants will intubate the hemoptysis cadaver model in simulation with videolaryngoscopy using McGrath and the short curved blade (XBlade) and a suction they will advanced directly before the optic of the camera. |
Timeline
- Start date
- 2019-03-11
- Primary completion
- 2019-06-30
- Completion
- 2019-06-30
- First posted
- 2019-09-12
- Last updated
- 2019-09-12
Locations
1 site across 1 country: Canada
Source: ClinicalTrials.gov record NCT04087135. Inclusion in this directory is not an endorsement.