Clinical Trials Directory

Trials / Withdrawn

WithdrawnNCT04021927

Development of a Neonatal Jaundice Treatment Accelerator by Redirection of Unused Light During Phototherapy

Status
Withdrawn
Phase
N/A
Study type
Interventional
Enrollment
0 (actual)
Sponsor
University of Minnesota · Academic / Other
Sex
All
Age
7 Days
Healthy volunteers
Not accepted

Summary

This is a descriptive prospective study of safety and efficacy of the reflective PT ring device. Neonates with an elevated total serum bilirubin (TSB) meeting PT criteria per their clinician during hospital admission will be eligible for enrollment after informed parental consent.

Detailed description

Neonatal jaundice (NNJ) continues to be a significant global problem affecting over 80% of neonates while severe neonatal jaundice affects at least 481,000 neonates annually. Jaundice and jaundice related complications like Kernicterus Spectrum Disorder (KDS) are gaining recognition among the world's health policy leaders as an important area for further research and development. The long-term sequelae of KSD include choreoathetoid cerebral palsy, sensorineural hearing loss, and upward gaze palsy. KSD is irreversible resulting in a lifetime of physical, emotional, social and economic challenges. Access to cost-effective methods of improving pediatric jaundice care along with improved circumferential (full body) illumination technologies is an affirmed objective of the AAP (American Academy of Pediatrics). The investigators hypothesize that unused therapy light (irradiance) surrounding the neonate using an existing single-lamp bank phototherapy (PT) device is sufficient in quantity and if redirected onto the patients untreated or poorly illuminated skin surfaces, it will accelerate metabolism and excretion of bilirubin. This PT ring device redirects unused phototherapy light sideways onto the neonate body using an open-faced ring approach. The technology will illuminate previously unexposed and poorly exposed skin regions where treatable bilirubin exists. The device is superior to current PT devices in that it converts existing waste light into treatment efficacy while integrating into existing overhead lamp systems offsetting the purchase of secondary devices that are often unaffordable and create hospital complexity, cost and inefficiency issues. A further benefit of the device will be reduced ambient blue-light spillover in patient care areas, an ongoing concern for medical staff.

Conditions

Interventions

TypeNameDescription
DEVICERing PhototherapyThe product will be an open-faced ring device with an angular reflective surface that redirects unused light sideways onto the neonate's body illuminating previously unexposed regions where treatable bilirubin exists while protecting the baby from head roll with an inner transparent corral. This device is superior to current PT devices because it converts existing waste light into treatment efficacy while integrating into existing single overhead lamp systems avoiding the purchase of secondary devices that are expensive and create hospital system complexity and inefficiency issues.

Timeline

Start date
2019-09-01
Primary completion
2021-01-01
Completion
2021-01-01
First posted
2019-07-16
Last updated
2021-02-23

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT04021927. Inclusion in this directory is not an endorsement.