Clinical Trials Directory

Trials / Completed

CompletedNCT04006665

Role of Lung Ultrasonography in Diagnosing Atelectasis in Robotic Pelvic Surgeries

Status
Completed
Phase
Study type
Observational
Enrollment
50 (actual)
Sponsor
Rajiv Gandhi Cancer Institute & Research Center, India · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

General anaesthesia results in developement of atelectasis in dependent areas of the lungs exposing patients to an increased risk of hypoxaemia.During pelvic robotic surgeries pneumoperitoneum and steep trendelenburg position further increases atelectasis. Lung Ultrasound imaging is a promising , noninvasive , non-radiant, portable tool to study intraoperative lung atelectasis.

Detailed description

Methodology -In the Operation Room 5 lead Electrocardiogram (ECG) , Pulse Oximetry (SPO2 ) , Noninvasive blood pressure (NIBP), End tidal carbon di Oxide (ETCO2 )and core temperature will be monitored , intravenous assess will be established with large bore cannula ,under Local anesthesia Radial artery cannulation will be performed , standard general anesthesia with oral cuffed Endotracheal tube and Intermittent Positive Pressure Ventilation (IPPV ) will be provided to all patients.Anaesthesia will be induced with Fentanyl 1-2 mcg/kg-1 , Morphine 0.5mg/kg-1 ,Propofol sleeping dose , Atracurium 0.5mg/kg-1,and maintained with Air/O2 Sevoflurane , Propofol infusion @100- 150 mcg/kg-1 to maintain Bispectral Index (BIS) between 40 -60 and atracurium infusion to maintain Train -of - Four (TOF Ratio) \< 0.5 Baseline Lung Ultrasound Imaging will be performed to record 4 point Lung aeration score ( 0= Normal lung /No aeration loss , 1= mild aeration loss, 2=moderate aeration loss ,3=severe aeration loss ) at T1 - 5 minutes after induction of anaesthesia and before docking robotic instruments in 6 basal zones in both lungs ( 3 zones in each lung ) and labelled as Zone I (Right anterior basal ) Zone II ( Right lateral basal) and Zone III (Right posterior basal) . Zone IV ( Left anterior basal) , Zone V (Left lateral basal ) , Zone VI ( Left Posterior basal ).T2 - Lung Ultrasound Imaging will be performed to record aeration score after removal of robotic arms at the end of robotic surgery and before extubation in 6 basal zones in both lungs.Ti Arterial blood gas 5 minutes after induction of anesthesia and before docking robotic instruments.Tii -Arterial blood gas 5 minutes after the end of robotic surgery and de docking robotic instruments.All patients will receive Positive End Expiratory Pressure (PEEP) 5 cms of water (H2O) intraoperatively . Intraabdominal Pressure will be maintained at 15 cms H2O. Any decrease in Oxygen saturation \< 96 % and intervention required will be noted. At the end of surgery , neuromuscular blockade will be reversed , trachea extubated and patient shifted to Postanaesthesia Care Unit.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTLung Ultrasonography (Baseline)Lung Ultrasonography will be performed prior to docking Robotic arms in basal three lung zones on both sides.
DIAGNOSTIC_TESTLung Ultrasonography ( At the end of surgery)Lung Ultrasonography will be performed after removal of Robotic arms and before extubation in basal three lung zones on both sides to assess degree of atelectasis.

Timeline

Start date
2019-09-01
Primary completion
2020-02-19
Completion
2020-02-28
First posted
2019-07-05
Last updated
2023-04-21

Locations

1 site across 1 country: India

Source: ClinicalTrials.gov record NCT04006665. Inclusion in this directory is not an endorsement.