Trials / Completed
CompletedNCT04000672
Patient Specific Instrumentation (PSI) Referencing Osteotomy Technological Transfer - a Randomized Control Trial (RCT)
Patient Specific Instrumentation (PSI) Referencing Osteotomy Technological Transfer and Education - a PSI High Tibial Osteotomy, Double-blinded, Randomized Controlled Trial - the PROTECTED HTO (High Tibial Osteotomy) Trial
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 40 (actual)
- Sponsor
- Chinese University of Hong Kong · Academic / Other
- Sex
- All
- Age
- 18 Years – 70 Years
- Healthy volunteers
- Not accepted
Summary
Medial open wedge high tibial osteotomy is a surgery performed to treat knee osteoarthritis in young patients.Recently with our department advance of technology, the investigators performed computed tomography for the patient's lower limb and 3D reconstruct the image. Based on the 3D image, the investigators planned our planned osteotomy cut on computer software Materialize 3 and the investigators then 3D printed a metal jig that has a slot to produce the osteotomy and also protected the neurovascular bundles. Therefore these metal jigs are specific to each patients. The investigators have performed a few cases of HTO under this extra metal jig protection and guidance and noted it has improved accuracy and safety clinically. However, whether it has scientific significance difference in accuracy is not known.
Detailed description
Medial open wedge high tibial osteotomy is a surgery performed to treat knee osteoarthritis in young patients. Currently the investigators perform high tibial osteotomy under the guidance of computer navigation to achieve the required alignment. During conventional high tibial osteotomy the bone cut is done by free hand cutting, there are risks of cutting into the posterior proximal tibia compartment and transect the neurovascular bundles which is a surgical disaster and may then lead to loss of limb. And the accuracy of free hand cutting is limited by experience of surgeons. In our conventional high tibial osteotomy transection of neurovascular bundles has never happened given our meticulous surgical technique but the investigators believe an extra protection is always beneficial to our patients. Recently with our department advance of technology, the investigators performed computed tomography for the patient's lower limb and 3D reconstruct the image. Based on the 3D image, the investigators planned our planned osteotomy cut on computer software Materialize 3 and the investigators then 3D printed a metal jig that has a slot to produce the osteotomy and also protected the neurovascular bundles. Therefore these metal jigs are specific to each patients. The investigators have performed a few cases of HTO under this extra metal jig protection and guidance and noted it has improved accuracy and safety clinically. However, whether it has scientific significance difference in accuracy is not known.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | 3D printed patient specific metal jigs (PSI jig) | PSI jig is created based on the pre-operative CT image. Standard medial open wedge osteotomy described previously is performed. Incision is made in the midway between posteromedial border of the tibia and medial aspect of the tibial tuberosity. Sartorius fascia is cut and retracted medially to expose the medial collateral ligament (MCL). Then the PSI jig is positioned onto the tibia. Due to the jig patient specific design (individually based on each patient's CT image), it can fit closely to the proximal tibia. The slot opening on the PSI jig corresponds to 4 cm below the medial joint line and the slot design allow the sawblade cut direction toward the safe zone of the lateral cortex under fluoroscopy. The PSI Jig is removed after the bone cut completed and would not retain in patient's body. |
| PROCEDURE | HTO with navigation | In brief, an incision is made in the midway between posteromedial border of the tibia and medial aspect of the tibial tuberosity. Sartorius fascia is cut and retracted medially to expose the medial collateral ligament (MCL). Two to three K-wires are placed 4 cm below the medial joint line toward the safe zone (an area between the tip of the fibular head and the remnant of fibular head epiphysis line) of the lateral cortex under fluoroscopy and osteotomy is done below and parallel to the k-wires using an oscillating saw leaving the lateral 10 mm intact. |
Timeline
- Start date
- 2019-07-01
- Primary completion
- 2023-12-06
- Completion
- 2023-12-06
- First posted
- 2019-06-27
- Last updated
- 2023-12-07
Locations
1 site across 1 country: Hong Kong
Source: ClinicalTrials.gov record NCT04000672. Inclusion in this directory is not an endorsement.