Clinical Trials Directory

Trials / Completed

CompletedNCT03995329

Acute Effects of a Heat-not-burn Tobacco Product on Pulmonary Function in Healthy Non Smokers.

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
25 (actual)
Sponsor
Aristotle University Of Thessaloniki · Academic / Other
Sex
Male
Age
18 Years – 55 Years
Healthy volunteers
Accepted

Summary

IQOS ("I-Quit-Ordinary-Smoking,") is a type of "heat-not-burn" (HNB) tobacco product. There is evidence of a growing number of young people who try IQOS as a 'safe' alternative of cigarette. The effect of the acute exposure to IQOS smoke on pulmonary function of healthy non smokers has not been studied extensively. Objectives: Evaluation of the acute effects of IQOS on pulmonary function,exhaled CO, O2 Saturation, arterial pressure and heart rate. Methods: Healthy non smokers, underwent exhaled CO measurement, spirometry including flows, volumes and diffusion capacity, and measurement of their respiratory resistances at 5, 10 and 20 Hz (R5Hz, R10Hz and R20Hz) with the use of an impulse oscillometry system (IOS) before and after the use of an IQOS. Additionally heart rate and arterial blood pressure were also measured.

Detailed description

All participants underwent pulmonary function tests (PFT) (MasterScreen PFT, Jaeger, Wurzburg, Germany) and total respiratory resistances measurement with an impulse oscillometry system (IOS)( (Viasys Jaeger MasterScreen IOS system).From the basic pulmonary measurements (flows and dynamic lung volumes), Forced Expiratory Volume in 1 second (FEV1), Forced Vital Capacity (FVC), Tiffenau index (FEV1/FVC, FEV1%), Peak Expiratory Flow (PEF), Maximal Expiratory Flow (MEF) at 25%, 50%, and 75% of vital capacity, Functional Residual Capacity (FRC), Total Lung Capacity (TLC), Residual Volume (RV), Diffusion Capacity (DLCO) were measured. Each manoeuvre was repeated for at least three technically acceptable forced expiratory flow curves in order to attain the best results. Respiratory impedance at 5 Hz (Z5Hz) and respiratory resistance at 5, 10, and 20 Hz (R5Hz, R10Hz, and R20Hz, respectively), reactance at 5, 10, and 20 Hz and resonant frequency were assessed with IOS. Heart rate, saturation of O2 (oxymetry) and arterial blood pressure were also measured. Exhaled CO measurement (piCO Smokerlyzer,Bedfont Scientific Ltd, Kent, U.K.) was performed After smoking heated tobacco (IQOS): 5 minutes after smoking IQOS , they repeated again PFTs, IOS, exhaled CO heart rate, saturation of O2 (oximetry) and arterial blood pressure measurements.

Conditions

Interventions

TypeNameDescription
OTHERIQOSAcute effects of IQOS on pulmonary function, oxygen saturation, exhaled CO, heart rate and arterial blood pressure.

Timeline

Start date
2019-06-19
Primary completion
2019-07-10
Completion
2019-07-10
First posted
2019-06-24
Last updated
2020-01-09

Locations

2 sites across 1 country: Greece

Source: ClinicalTrials.gov record NCT03995329. Inclusion in this directory is not an endorsement.