Trials / Completed
CompletedNCT03954548
CB-17-08 Augmented Endoscopy System for Mucosal Lesion Detection During Colonoscopy for Colon Rectal Cancer.
Prospective, Randomized, Multicenter, Tandem Study Evaluating the Safety and Effectiveness of the CB-17-08 Augmented Endoscopy System for the Detection of Mucosal Colorectal Polyps in Adult Patients Undergoing Screening or Surveillance Colonoscopy for CRC.
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 249 (actual)
- Sponsor
- Cosmo Artificial Intelligence-AI Ltd · Industry
- Sex
- All
- Age
- 45 Years
- Healthy volunteers
- Accepted
Summary
The aim of this study is to assess the performance of the CB-17-08 to help endoscopists find potential mucosal polyps during the colonoscopy procedure, without significant noise disturbing the endoscopist attention, nor negative interference with the lesions detection than with the standard colonoscopy alone: the study will investigate whether the use of the device provides an increase in the number of adenomas per colonoscopy as compared to standard colonoscopy. The study will also evaluate the safety of the CB-17-08, assessing if the use of the system increases the total number of excisions without a commensurate number of adenomas as compared to standard colonoscopy.
Detailed description
Study procedure: Patients will be randomized (1:1) to one of the arms by an IWRS system. Randomization will be stratified by study endoscopist, to balance the number of patients randomized to either of the study groups (1:1) within the same endoscopist, by age (from to 45 to \<65 years old; ≥65 years old) and by reason for colonoscopy (screening, surveillance \<3 years from previous colonoscopy, surveillance 3-10 years from previous colonoscopy). Each endoscopist shall not enrol more than 90 patients. The following study visits are foreseen for each patient: Screening Visit A screening visit is performed at the investigational site. During this visit out-patients scheduled for colonoscopy will be informed about the aims, procedures, benefits and possible risks of the study prior to signing the informed consent form for inclusion in the study. Their medical history will be recorded as well as eventual clinical or laboratory examinations according to the local standard of care preparation for a colonoscopy, ) and the date for the colonoscopy procedure to be performed at the investigational site will be scheduled. Tandem Colonoscopy Visit Each eligible patient returns to the clinic to undergo a same-day, back-to-back tandem colonoscopy examination performed by the same experienced endoscopist. The randomized allocation will determine whether patients will undergo standard high-definition white light colonoscopy with CB-17-08 immediately followed by standard high definition white light colonoscopy or standard high definition white light colonoscopy followed by standard high definition white light colonoscopy with CB-17-08. Bowel preparation will be done according to the usual standard of care protocols of the individual sites. The quality of bowel preparation will be assessed during colonoscopy using the Boston Bowel Preparation Scale (BBPS). Sedation according to the sites best experience and standard procedures will be delivered to the patient by the endoscopist or an anaesthesiologist. Subjects' vital signs (blood pressure \[BP\], hearth rate \[HR\] and oxygen saturation \[SpO2\]) will be measured and monitored prior to, during and at the end of the tandem colonoscopy procedure. The endoscopist will be instructed to adhere to their usual withdrawal technique and to spend a minimum of 6 minutes withdrawing and examining the colonic mucosa. Time to reach the caecum and time to withdrawal from caecum to exit will be recorded for each colonoscopy. Clean withdrawal time, i.e. withdrawal time excluding the time spent for procedures or washings (if any), will be recorded. At least 6 minutes of clean withdrawal time will be required for all colonoscopies, in accordance to the current ASGE guideline. Withdrawal time, total procedure time, and time for pauses to allow polypectomies and biopsies to be performed will be recorded. Repeated examination of any of the colon segments (e.g. right colon) in normal modality or in retroflexion is not permitted. Each colorectal polyp detected during the first procedure, as well as each polyp detected during the second procedure, will be immediately removed or biopsied and will be sent to the central histology laboratory for characterization. When a mucosal polyp is detected, its estimated size and morphological appearance according to Paris classification will be reported by the endoscopist on the CRF, as well as the anatomical location inside the colonic districts. On the basis of histological examination, polyps will be categorized according to revised Vienna classification and serrated lesion classification.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | CB-17-08 CADe | CB-17-08 Augmented Endoscopy System with Computer Aided Detection (CADe) function |
Timeline
- Start date
- 2020-02-17
- Primary completion
- 2021-05-07
- Completion
- 2021-05-07
- First posted
- 2019-05-17
- Last updated
- 2021-05-12
Locations
10 sites across 3 countries: United States, Italy, United Kingdom
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT03954548. Inclusion in this directory is not an endorsement.