Clinical Trials Directory

Trials / Withdrawn

WithdrawnNCT03924063

Safety of the Hemiverse Shoulder Prothesis

Status
Withdrawn
Phase
N/A
Study type
Interventional
Enrollment
0 (actual)
Sponsor
Balgrist University Hospital · Academic / Other
Sex
All
Age
65 Years
Healthy volunteers
Not accepted

Summary

This clinical trial investigates the safety and the preliminary clinical benefit of the hemiverse shoulder prosthesis. Implantation of this newly developed hemi-prosthesis is intended for patients who do not qualify for a regular reverse or hemi-prosthesis due to severe medical conditions, poor bone stock or critical status of the rotator cuff. The expected benefit is, that patients will have a minimally invasive surgical procedure, only addressing the humeral shaft, however with the biomechanical advantage of a total reverse shoulder prosthesis, meaning, that with a minimally invasive surgery a comparable result as with a regular total shoulder prosthesis is accomplished. Patients will be closely monitored within the study protocol for 18 months and thereafter in regular interval was as with a normal prosthetic followup.

Detailed description

This clinical trial investigates the safety and the preliminary clinical benefit of the hemiverse shoulder prosthesis. Implantation of this newly developed hemi-prosthesis is intended for patients who do not qualify for a regular reverse or hemi-prosthesis due to severe medical conditions, poor bone stock or critical status of the rotator cuff. To evaluate the clinical condition of the patient a clinical examination with thorough control of the blood parameters (hemoglobin, leucocytes, platelets, infection parameters) and including constant score and the quick dash score will be performed before the operation. To evaluate the bone stock and the musculature a conventional radiological status and a computed tomography of the shoulder will be performed. Surgical procedure: A delto-pectoral approach is preferred. The incision starts immediately lateral to the coracoid tip and extends to the insertion of the deltoid on the Humerus. The subscapularis tendon is exposed and detached from the humerus. The humeral head is exposed and dislocated from the joint using an oscillating saw the humeral head is resected. The shaft is prepared to receive a regular humeral stem which is definitely implanted with 0° retroversion. A trial implant is inserted and reduced into the joint. Free mobility of the joint is tested and the stability of the implant documented. According to the trial implants the definite implant is assembled and implanted. After reduction of the implant the subscapularis tendon is reattached to the humerus using transosseous sutures. Regular closure of the incision is performed. After-care: Immediately post operatively a anteroposterior radiograph is performed. For the first two post-operative weeks the arm is immobilised in a sling and external rotation is allowed until 0° and flexion until 90° in internal rotation. Thereafter gradual increase of active mobility is allowed until the weeks post operatively, when full load bearing of the arm is allowed. Regular followup visits include a constant score, quick dash-score and conventional radiographic status(anteroposterior lateral and axillary view) and are performed to be post-operative 3 months 6 months 1 year and 18 months post operatively.

Conditions

Interventions

TypeNameDescription
DEVICEHemiverseImplantation of the hemiverse shoulderprothesis

Timeline

Start date
2021-05-14
Primary completion
2021-05-14
Completion
2021-05-14
First posted
2019-04-23
Last updated
2023-03-15

Locations

1 site across 1 country: Austria