Clinical Trials Directory

Trials / Unknown

UnknownNCT03910985

Assessment of Reactance Parameters Measured by the Forced Oscillation Technique for the Bronchodilator Response in Subjects With Chronic Obstructive Pulmonary Disease (COPD)

Status
Unknown
Phase
Phase 4
Study type
Interventional
Enrollment
80 (estimated)
Sponsor
Centre Hospitalier Universitaire UCLouvain Namur · Academic / Other
Sex
All
Age
40 Years
Healthy volunteers
Not accepted

Summary

The aims of this study is : * to assess the bronchodilator (DUOVENT HFA) response of parameters measured by the forced oscillations (FOT) and in particular the reactance parameters related to the presence of a limitation of expiratory flows * to compare the response of the reactance parameters to bronchodilators with the conventional spirometric parameters (FEV1) and inspiratory capacity (IC), and according to the severity of the disease * to assess and compare the relationship between the response to bronchodilators in terms of IC on the one hand and on the other hand in terms of FEV1, reactance parameters (measured by FOT), resistance parameters (measured by plethysmography and FOT) * Assess and compare the relationship between dyspnea intensity assessed by various scales and conventional respiratory function parameters (spirometry, plethysmography, diffusion indices) and parameters measured by FOT

Detailed description

Different techniques will be used during this study : First, the FOT. The measurements will be performed using a Tremoflo-type (Thorasys Thoracic Medical System Inc.) device that generates an oscillating pressure waveform and measures impedance of the respiratory system and its components (resistance and reactance) as a function of frequency, as well as the respiratory system resonant frequency. Measurements will be performed during tidal breathing, the subjects breathing through the pneumotachograph of the system, with nose occluded, the cheeks supported by the hands (of the subjects or of an operator) to reduce the influence of the compliant upper airways. Three measurements of minimum 20 seconds duration will be recorded in the sitting position. Second, the spirometry. The measurements will be carried out using a Medisoft Exp'air type of equipment. The parameters will be successively measured in the sitting position : * The inspiratory capacity (IC) will be measured by maximal inspiratory maneuver starting from the functional residual capacity * The thoracic gas volume (TGV), total lung capacity (TLC), as well as the airway resistance will be measured by plethysmography * The diffusion indices (CO transfer factor (DL,CO) and CO transfer coefficient (KCO)) will be measured in apnea * A spirometry will then be carried out. Three maneuvers with acceptability and reproducibility criteria will be performed All these measurements will be carried out before the administration of the bronchodilator and 30 minutes after the administration of the bronchodilator (4 puffs of DUOVENT HFA, using an inhalation chamber).

Conditions

Interventions

TypeNameDescription
DRUGDuovent HFAbronchodilation

Timeline

Start date
2019-04-23
Primary completion
2021-12-31
Completion
2021-12-31
First posted
2019-04-10
Last updated
2019-04-17

Source: ClinicalTrials.gov record NCT03910985. Inclusion in this directory is not an endorsement.