Clinical Trials Directory

Trials / Unknown

UnknownNCT03837197

Clinical Trial of New Hypothermic Oxygenated Perfusion System Versus Static Cold Storage

Expanded Criteria Donors in Liver and Kidney Transplantation: Protocol of a Randomised Single Center Clinical Trial of Hypothermic Oxygenated Perfusion Versus Static Cold Storage

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
220 (estimated)
Sponsor
University of Bologna · Academic / Other
Sex
All
Age
18 Years – 100 Years
Healthy volunteers
Not accepted

Summary

With the present study the investigators will evaluate the benefit of end-ischemic HOPE on ECD grafts (livers and kidneys) as compared to SCS. Organs will be perfused through a recently developed machine perfusion (MP) device, from the beginning of back-table procedures till implantation, without increasing CIT. The aim of the study will be demonstrating the ability of HOPE to improve graft function and post-operative outcomes of ECD kidney and liver recipients.

Detailed description

Extended criteria donors (ECD) are widely utilized due to organ shortage, but this may increase the risk of graft dysfunction and of poorer outcomes. Hypothermic oxygenated perfusion (HOPE) is a recent organ preservation strategy for marginal kidney and liver grafts, which allows to redirect anaerobic metabolism to aerobic metabolism under hypothermic conditions and to protect grafts from oxidative species-related damage; these mechanisms may potentially improve graft function and survival. Methods This is an open-label, randomized multicenter clinical trial with the aim of comparing HOPE vs. static cold storage (SCS) in ECD kidney and liver transplantation. In the study protocol - approved by ethics committee - 220 patients (110 liver recipients and 110 kidney recipients) will be enrolled. Livers and kidneys assigned to HOPE will be perfused by machine perfusion with cold Belzer solution (4°-10°C) and with continuous oxygenation (partial pressure of oxygen = 500-600 mmHg). In the control group, livers and kidneys undergoing SCS will be steeped in Celsior or University of Wisconsin Belzer solutions and stored in ice. Using the same perfusion machine for both liver and kidney grafts, organs will be perfused from the start of the back-table procedure until implantation, without increasing cold ischemia time (CIT). For each group the investigators will evaluate clinical outcomes, graft function tests and histologic findings, as well as perfusate and the number of allocated organs.

Conditions

Interventions

TypeNameDescription
DEVICEKidney-Hypothermic oxygenatedKidney perfusion will be performed through the renal artery at 25-30 mmHg pressure. Flow, pressure and temperature will be monitored and registered on a Universal Serial Bus (USB) memory system during organ perfusion. Gas analysis of the effluent perfusate will be accomplished at the start of perfusion (T0) then every 30 minutes. Two perfusate samples will be collected at the beginning and at the end of perfusion to rule out bacterial or fungal contamination. HOPE will start by flushing the organ at low flow values (20 ml/min) with new oxygenated perfusion fluid during back-table preparation. Organ will be treated with continuous HOPE until transplant. Organ perfusion will be continuously monitored. Minimal perfusion time will be 2 hours for kidneys.
DEVICELiver-Hypothermic oxygenatedLiver perfusion will be performed through the portal vein at a 5 mmHg pressure. Flow, pressure and temperature will be monitored and registered on a Universal Serial Bus (USB) memory system during organ perfusion. Gas analysis of the effluent perfusate will be accomplished at the start of perfusion (T0) then every 30 minutes. Two perfusate samples will be collected at the beginning and at the end of perfusion to rule out bacterial or fungal contamination. HOPE will start by flushing the organ at low flow values (30 ml/min) with new oxygenated perfusion fluid during back-table preparation. Organ will be treated with continuous HOPE until transplant. Organ perfusion will be continuously monitored. Minimal perfusion time will be 1 hour for livers.

Timeline

Start date
2018-12-21
Primary completion
2019-12-01
Completion
2021-12-01
First posted
2019-02-12
Last updated
2019-09-27

Locations

1 site across 1 country: Italy

Source: ClinicalTrials.gov record NCT03837197. Inclusion in this directory is not an endorsement.