Clinical Trials Directory

Trials / Unknown

UnknownNCT03827681

To Study the Efficacy and Safety of TIPS (Trans Intrahepatic Portosystemic Shunt) Versus Self Expanding Metallic Stent (SEMS) in the Management of Refractory Variceal Bleed in Cirrhotics.

A Randomised Controlled Trial to Study the Efficacy and Safety of TIPS (Trans Intrahepatic Portosystemic Shunt) Versus Self Expanding Metallic Stent (SEMS) in the Management of Refractory Variceal Bleed in Cirrhotics.

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
50 (estimated)
Sponsor
Institute of Liver and Biliary Sciences, India · Academic / Other
Sex
All
Age
18 Years – 70 Years
Healthy volunteers
Not accepted

Summary

A total of 50 patients will be enrolled and will be randomized into either Group A(TIPS) or Group B (SEMS). Primary end point of the study will be to compare efficacy of TIPS versus SEMS for survival at 6 week or Early re Bleed. All enrolled patients will also undergo HVPG measurement at baseline to stratify risk of failure to control bleed or early re-bleed. Patient will be monitored for 5 days for re bleed, complications of therapy, worsening of Liver function tests and scores and efficacy of either treatment modality over other. Patient will be followed for 6 weeks to see for the primary end point.

Conditions

Interventions

TypeNameDescription
PROCEDURETrans Intrahepatic Portosystemic Shunt* The most common approach is through the right internal jugular approach. * After infiltrating the puncture site with 2% lignocaine and puncturing the vein a guide wire is advanced into the IVC followed by a 9F/10F vascular sheath. * A wedged venogram is performed with a peripherally placed hepatic vein catheter, which may identify a portion of the portal vein to facilitate subsequent puncture.' * A stiff guide wire is then passed through the catheter and the vascular sheath is advanced into the right hepatic vein. With the vascular sheath in place a rigid needle with 15-20 degrees of distal angulation is advanced over the guide wire and through the vascular sheath to enter the hepatic vein.
PROCEDURESelf Expanding Metallic Stent* At upper endoscopy, a 0.35 Superstiff radiological guidewire with a soft tip (supplied with the stent insertion kit) is delivered into the stomach under direct vision and the endoscope is removed. * The stent delivery device is then advanced over the guidewire into the stomach, and the distal portion of the stent delivery system is withdrawn to allow inflation of the gastric balloon. * The gastric balloon is then inflated with 100 mL of air, and the whole delivery system is withdrawn until resistance is felt, which signifies that the balloon is impacting at the cardia, thus anchoring the distal end of the stent during deployment. * After stent deployment, the gastric balloon is deflated and the stent delivery system is withdrawn. The stent is then examined endoscopically. When deployed, the stent is 135 mm long and 25 mm wide.
DRUGVasoactive AgentVasoactive Agent

Timeline

Start date
2019-02-06
Primary completion
2020-06-30
Completion
2020-06-30
First posted
2019-02-01
Last updated
2020-03-10

Locations

1 site across 1 country: India

Source: ClinicalTrials.gov record NCT03827681. Inclusion in this directory is not an endorsement.