Clinical Trials Directory

Trials / Completed

CompletedNCT03817723

Radiation Exposure in Intraoperative Cholangiography

Radiation Exposure of Intraoperative Cholangiography During Cholecystectomy

Status
Completed
Phase
Study type
Observational
Enrollment
324 (actual)
Sponsor
Jyväskylä Central Hospital · Academic / Other
Sex
All
Age
Healthy volunteers
Not accepted

Summary

Aims: to determine the radiation exposure of routine intraoperative cholangiography (IOC )during cholecystectomy and examine the factors affecting radiation dose and fluoroscopy time (FT). Methods: 598 intraoperative cholangiography examinations were performed at the Central Finland Central Hospital. In this study we included 324 intraoperative cholangiographies performed with c-arm equipment not exceeding 10 years of age.

Detailed description

From January 2016 to December 2017, consecutive 598 intraoperative cholangiography examinations were performed at the Central Finland Central Hospital. In this study we included 353 cholangiographies, that were performed with our c-arm equipment not exceeding 10 years of age in the beginning of 2016. The main measures of outcome were the recorded radiation dose data of c-arm systems from our manual database . Another 25 cases were excluded because it was not possible to cross-check the manually recorded radiation dose data from the Picture Archiving and Communication System (PACS ). Additional 4 patients who underwent intraoperative endoscopic retrograde cholangiopancreatography (ERCP) were removed from the radiation exposure analysis because IOC and ERCP were performed consequently with the same c-arm and the radiation exposure of IOC could not be separated from the registered total KAP and FT. Thus the final analysis consisted of 324 IOCs. KAP (Kerma area product) is the product of air Kerma in the center of the imaging area multiplied with size of the imaging area. For simplicity we have unified varying units received from different c-arms and will only use Gray multiplied by square centimeters (Gycm2 ). KAP values were measured using inbuilt ionization chambers in c-arms. For this study we collected the KAP values from exposure and pulsed fluoroscopy. We also recorded the fluoroscopy time (s). Laparoscopic cholecystectomies were performed both by residents and specialist surgeons. Ethics: No ethical approval or written informed consent were needed because the study was retrospective in nature. The study was approved by the hospital administration.

Conditions

Interventions

TypeNameDescription
RADIATIONc-arm cholangiography

Timeline

Start date
2016-01-01
Primary completion
2017-12-31
Completion
2018-09-01
First posted
2019-01-25
Last updated
2019-01-25

Locations

1 site across 1 country: Finland

Source: ClinicalTrials.gov record NCT03817723. Inclusion in this directory is not an endorsement.